| Assessment Year | 1996 |
|---|---|
| Principal Product | Injection Molded Plastic Parts |
| NAICS |
n/a
|
| SIC | 3751: Motorcycles, Bicycles, and Parts |
| Sales Range | $10 M to 50M |
| # of Employees | 42 |
| Plant Area |
75,000
ft2
|
| Annual Production | 500,000
pieces
|
| Production Hrs. Annual | 4,550
hrs
|
| Location (State) | California |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $64,131 | 494,431 |
kWh
|
$0.13 |
| Electricity Demand | $10,583 | 1,012 |
kW-mo/yr
|
$10.46 |
| Natural Gas | $2,842 | 392 |
MMBtu
|
$7.25 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $11,525 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $4,535 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Water Disposal Savings |
|---|---|---|---|---|---|---|
| 01 | 2.2511: Insulate bare equipment | $3,660 | $1,960 |
$3,660
28,136
kWh
|
- | |
| 02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,987 | $700 |
$1,987
15,240
kWh
|
- | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $632 | $170 |
$632
4,982
kWh
|
- | |
| 04 | 2.7135: Install occupancy sensors | $1,338 | $227 |
$1,338
10,258
kWh
|
- | |
| 05 | 2.7144: Install spectral reflectors / delamp | $3,197 | $600 |
$3,197
24,619
kWh
|
- | |
| 06 | 3.4151: Minimize water usage | $711 | $900 | - |
$711
-
Tgal
|
|
| TOTAL RECOMMENDED | $11,525 | $4,557 |
$10,814
83,235
kWh
|
$711
-
Tgal
|
||
| TOTAL IMPLEMENTED | $4,535 | $827 |
$4,535
34,877
kWh
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Water Disposal Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs