Assessment Year | 1995 |
---|---|
Principal Product | Multi-Part Business Forms |
NAICS |
n/a
|
SIC | 2761: Manifold Business Forms |
Sales Range | $5 M to 10M |
# of Employees | 60 |
Plant Area |
45,000
ft2
|
Annual Production | 44,400,000
pieces
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Nevada |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $124,422 | 1,907,679 |
kWh
|
$0.065 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $12,757 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $10,310 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.7111: Reduce illumination to minimum necessary levels | $2,702 | $175 |
$2,702
31,653
kWh
|
|
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,457 | $978 |
$5,457
85,580
kWh
|
|
03 | 2.7135: Install occupancy sensors | $1,544 | $736 |
$1,544
33,705
kWh
|
|
04 | 2.1131: Repair faulty insulation in furnaces, boilers, etc | $903 | $911 |
$903
19,637
kWh
|
|
05 | 2.4133: Use most efficient type of electric motors | $2,151 | $4,335 |
$2,151
43,669
kWh
|
|
TOTAL RECOMMENDED | $12,757 | $7,135 |
$12,757
214,244
kWh
|
||
TOTAL IMPLEMENTED | $10,310 | $5,488 |
$10,310
160,902
kWh
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs