Assessment Year | 1995 |
---|---|
Principal Product | Rolled, Sheet, and Tube Steel Products |
NAICS |
n/a
|
SIC | 3443: Fabricated Plate Work (Boiler Shops) |
Sales Range | $5 M to 10M |
# of Employees | 65 |
Plant Area |
71,600
ft2
|
Annual Production | 2,500
ton
|
Production Hrs. Annual | 2,730
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $83,060 | 714,244 |
kWh
|
$0.12 |
Natural Gas | $10,506 | 1,619 |
MMBtu
|
$6.49 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $8,053 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $1,566 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $1,149 | $709 |
$1,149
8,206
kWh
|
|
02 | 2.7145: Install skylights | $6,192 | $20,963 |
$6,192
44,549
kWh
|
|
03 | 2.7135: Install occupancy sensors | $295 | $164 |
$295
2,052
kWh
|
|
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $417 | $100 |
$417
2,931
kWh
|
|
TOTAL RECOMMENDED | $8,053 | $21,936 |
$8,053
57,738
kWh
|
||
TOTAL IMPLEMENTED | $1,566 | $809 |
$1,566
11,137
kWh
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs