Assessment Year | 1995 |
---|---|
Principal Product | Wood Mouldings |
NAICS |
n/a
|
SIC | 2431: Millwork |
Sales Range | $10 M to 50M |
# of Employees | 50 |
Plant Area |
130,000
ft2
|
Annual Production | 6,000,000
units
|
Production Hrs. Annual | 2,990
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $134,113 | 1,405,334 |
kWh
|
$0.095 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $21,328 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $10,617 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $6,998 | - |
$6,998
74,736
kWh
|
|
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,930 | $888 |
$1,930
20,223
kWh
|
|
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,689 | $200 |
$1,689
17,585
kWh
|
|
04 | 2.7421: Reduce glazed areas in buildings | $151 | $653 |
$151
1,465
kWh
|
|
05 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $10,560 | - |
$10,560
-
kWh
|
|
TOTAL RECOMMENDED | $21,328 | $1,741 |
$21,328
114,009
kWh
|
||
TOTAL IMPLEMENTED | $10,617 | $1,088 |
$10,617
112,544
kWh
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs