Assessment Year | 1994 |
---|---|
Principal Product | Laser Equipment |
NAICS |
n/a
|
SIC | 3827: Optical Instruments and Lenses |
Sales Range | $10 M to 50M |
# of Employees | 400 |
Plant Area |
105,000
ft2
|
Annual Production | 21,500
pieces
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $384,791 | 5,498,242 |
kWh
|
$0.070 |
Natural Gas | $27,614 | 4,864 |
MMBtu
|
$5.68 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $8,596 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $4,657 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $3,709 | $(-175.0) |
$3,709
53,341
kWh
|
- | |
02 | 2.7243: Improve air circulation with destratification fans / other methods | $2,218 | $3,780 | - |
$2,218
-
MMBtu
|
|
03 | 2.7135: Install occupancy sensors | $914 | $454 |
$914
12,016
kWh
|
- | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $554 | $240 |
$554
7,913
kWh
|
- | |
05 | 2.3212: Optimize plant power factor | $807 | $2,250 |
$807
-
kWh
|
- | |
06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $394 | $30 |
$394
5,569
kWh
|
- | |
TOTAL RECOMMENDED | $8,596 | $6,579 |
$6,378
78,839
kWh
|
$2,218
-
MMBtu
|
||
TOTAL IMPLEMENTED | $4,657 | $95 |
$4,657
66,823
kWh
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs