| Assessment Year | 2026 |
|---|---|
| Principal Product | Inverters for solar industry, PV modules, batteries, & balance of system components |
| NAICS | 423720: Plumbing and Heating Equipment and Supplies (Hydronics) Merchant Wholesalers |
| SIC | 5063: Electrical Apparatus and Equipment Wiring Supplies, and Construction Materials |
| Sales Range | $50 M to 100M |
| # of Employees | 100 |
| Plant Area |
267,500
ft2
|
| Annual Production | 50,000
units
|
| Production Hrs. Annual | 3,696
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $121,452 | 1,801,931 |
kWh
|
$0.067 |
| Electricity Demand | $27,847 | 3,342 |
kW-mo/yr
|
$8.33 |
| Electricity Fees | $471 | - |
|
- |
| TOTAL YEARLY COSTS | $149,770 | |||
| RECOMMENDED SAVINGS* | $182,873 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $113,007 | $65,000 | - | - | - | $113,007 | |
| 02 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $38,701 | $33,699 | - | - | - | $38,701 | |
| 03 | 2.8121: Apply for tax-free status for energy purchases | $14,662 | $5,000 | - | - | $14,662 | - | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $7,351 | $14,367 |
$5,295
78,564
kWh
|
$2,056
-
kW-mo/yr
|
- | - | |
| 05 | 2.7221: Lower temperature during the winter season and vice-versa | $5,733 | - |
$5,733
85,054
kWh
|
- | - | - | |
| 06 | 2.4133: Use most efficient type of electric motors | $3,419 | $16,403 |
$3,419
50,733
kWh
|
- | - | - | |
| TOTAL RECOMMENDED | $182,873 | $134,469 |
$14,447
214,351
kWh
|
$2,056
-
kW-mo/yr
|
$14,662 | $151,708 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | One-time Revenue or Avoided Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs