ITAC Assessment: NT0057
ITAC logo
ITAC Assessment: NT0057
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2026
Principal Product Inverters for solar industry, PV modules, batteries, & balance of system components
NAICS 423720: Plumbing and Heating Equipment and Supplies (Hydronics) Merchant Wholesalers
SIC 5063: Electrical Apparatus and Equipment Wiring Supplies, and Construction Materials
Sales Range $50
M
to 100
M
# of Employees 100
Plant Area 267,500
ft2
Annual Production 50,000
units
Production Hrs. Annual 3,696
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $121,452 1,801,931
kWh
Electricity Demand $27,847 3,342
kW-mo/yr
Electricity Fees $471 -
TOTAL YEARLY COSTS $149,770
RECOMMENDED SAVINGS* $182,873 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings One-time Revenue or Avoided Cost Savings
01 3.5315: Lease / purchase baler; sell cardboard to recycler $113,007 $65,000 - - - $113,007
02 3.5315: Lease / purchase baler; sell cardboard to recycler $38,701 $33,699 - - - $38,701
03 2.8121: Apply for tax-free status for energy purchases $14,662 $5,000 - - $14,662 -
04 2.7142: Utilize higher efficiency lamps and/or ballasts $7,351 $14,367 $5,295
78,564
kWh
$2,056
-
kW-mo/yr
- -
05 2.7221: Lower temperature during the winter season and vice-versa $5,733 - $5,733
85,054
kWh
- - -
06 2.4133: Use most efficient type of electric motors $3,419 $16,403 $3,419
50,733
kWh
- - -
TOTAL RECOMMENDED $182,873 $134,469 $14,447
214,351
kWh
$2,056
-
kW-mo/yr
$14,662 $151,708
TOTAL IMPLEMENTED - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs