| Assessment Year | 2026 |
|---|---|
| Principal Product | Cranes and Truck Bodies |
| NAICS | 336211: Motor Vehicle Body Manufacturing |
| SIC | 3713: Truck and Bus Bodies |
| Sales Range | $50 M to 100M |
| # of Employees | 170 |
| Plant Area |
200,000
ft2
|
| Annual Production | 3,200
units
|
| Production Hrs. Annual | 2,040
hrs
|
| Location (State) | Iowa |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $338,705 | 5,848,953 |
kWh
|
$0.058 | |
| Electricity Demand | $61,684 | 13,276 |
kW-mo/yr
|
$4.65 | |
| Electricity Fees | $14,473 | - |
|
- | |
| Natural Gas | $100,983 | 22,631 |
MMBtu
|
$4.46 | |
| Other Gas | $69,065 | 1 |
MMBtu
|
$69,065.00 | |
| Waste Disposal Costs | |||||
| Water Usage | $11,016 | 2,583 |
Tgal
|
$4.27 | |
| Water Disposal | $16,000 | 2,619 |
Tgal
|
$6.11 | |
| Other Liquid (non-haz) | $7,296 | 1 |
gal
|
$7,296.00 | |
| TOTAL YEARLY COSTS | $619,223 | ||||
| RECOMMENDED SAVINGS* | $41,299 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings | Increase in Production Savings |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.7243: Improve air circulation with destratification fans / other methods | $28,492 | $42,500 |
$1,626
28,030
kWh
|
$766
-
kW-mo/yr
|
- | - | - | - | $26,100 | |
| 02 | 2.2514: Cover open tanks | $5,486 | $22,260 | - | - |
$5,486
-
MMBtu
|
- | - | - | - | |
| 03 | 2.8121: Apply for tax-free status for energy purchases | $3,213 | $6,250 | - | - | - |
$3,213
-
MMBtu
|
- | - | - | |
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,694 | $200 |
$2,194
37,840
kWh
|
- | - | - | $(-400.0) | $(-100.0) | - | |
| 05 | 3.5311: Recover and reuse waste material | $1,264 | $5,200 | - | - | - | - | $590 | $674 | - | |
| 06 | 2.6218: Turn off equipment when not in use | $1,150 | $300 |
$1,150
19,832
kWh
|
- | - | - | - | - | - | |
| TOTAL RECOMMENDED | $41,299 | $76,710 |
$4,970
85,702
kWh
|
$766
-
kW-mo/yr
|
$5,486
-
MMBtu
|
$3,213
-
MMBtu
|
$190 | $574 | $26,100 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings | Increase in Production Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs