ITAC Assessment: NL0122
ITAC logo
ITAC Assessment: NL0122
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2025
Principal Product Adhesive Labels
NAICS 326113: Unlaminated Plastics Film and Sheet (except Packaging) Manufacturing
SIC 3081: Unsupported Plastics Film and Sheet
Sales Range $50
M
to 100
M
# of Employees 140
Plant Area 200,000
ft2
Annual Production 750,000
thousand feet
Production Hrs. Annual 6,732
hrs
Location (State) Nebraska

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $279,403 6,463,680
kWh
Electricity Demand $251,286 21,781
kW-mo/yr
Electricity Fees $4,924 -
Natural Gas $516,442 83,098
MMBtu
Other Gas $4,849 1
MMBtu
Waste Disposal Costs
Water Usage $10,190 3,279
Tgal
Water Disposal $10,126 1,181
Tgal
Other Liquid (non-haz) $1,591 1
gal
TOTAL YEARLY COSTS $1,078,811
RECOMMENDED SAVINGS* $84,593 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Personnel Changes Savings One-time Revenue or Avoided Cost Savings
01 2.2414: Use waste heat from hot flue gases to preheat $58,962 $417,000 - - $58,962
-
MMBtu
- -
02 2.3212: Optimize plant power factor $10,000 $15,600 - - - - $10,000
03 2.7142: Utilize higher efficiency lamps and/or ballasts $5,944 $13,202 $4,020
93,480
kWh
$1,924
-
kW-mo/yr
- - -
04 2.6218: Turn off equipment when not in use $5,864 $120 $9,434
219,375
kWh
- - $(-3,570.0) -
05 2.4111: Utilize energy-efficient belts and other improved mechanisms $1,650 $12,200 $636
14,794
kWh
$1,014
-
kW-mo/yr
- - -
06 2.8114: Change rate schedules or other changes in utility service $1,242 $120 - - - - $1,242
07 2.3131: Reschedule plant operations or reduce load to avoid peaks $931 $90 - $1,291
-
kW-mo/yr
- $(-360.0) -
TOTAL RECOMMENDED $84,593 $458,332 $14,090
327,649
kWh
$4,229
-
kW-mo/yr
$58,962
-
MMBtu
$(-3,930.0) $11,242
TOTAL IMPLEMENTED - - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Personnel Changes Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs