Assessment Year | 2022 |
---|---|
Principal Product | Salad Dressing |
NAICS | 311941: Mayonnaise, Dressing, and Other Prepared Sauce Manufacturing |
SIC | 2035: Pickled Fruits and Vegetables, Vegetable Sauces and Seasonings, and Salad Dressings |
Sales Range | $1 M to 5M |
# of Employees | 13 |
Plant Area |
64,000
ft2
|
Annual Production | 2,250,000
lb
|
Production Hrs. Annual | 2,000
hrs
|
Location (State) | Nebraska |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $63,767 | 1,441,067 |
kWh
|
$0.044 | |
Electricity Demand | $34,251 | 2,303 |
kW-mo/yr
|
$14.88 | |
Electricity Fees | $5,440 | - |
|
- | |
LPG | $8,770 | 459 |
MMBtu
|
$19.13 | |
Waste Disposal Costs | |||||
Water Usage | $10,766 | 6,987 |
Tgal
|
$1.54 | |
TOTAL YEARLY COSTS | $122,994 | ||||
RECOMMENDED SAVINGS* | $584,460 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $332,298 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | LPG Savings | Personnel Changes Savings | Primary Raw Material Savings | Ancillary Material Cost Savings | Increase in Production Savings |
---|---|---|---|---|---|---|---|---|---|---|---|
01 | 3.2172: Use automatic cleaning equipment | $250,000 | $215,120 | - | - | - | - | - | - | $250,000 | |
02 | 4.111: Add equipment/ operators to reduce production bottleneck | $250,000 | $150,000 | - | - | - | - | - | - | $250,000 | |
03 | 4.132: Purchase new equipment to reduce material use / cost | $49,500 | $95,000 | - | - | - | - | $49,500 | - | - | |
04 | 2.7232: Replace existing hvac unit with high efficiency model | $16,645 | $32,028 |
$32,108
338,000
kWh
|
- |
$(-15,462.6)
-
MMBtu
|
- | - | - | - | |
05 | 2.7243: Improve air circulation with destratification fans / other methods | $11,640 | $13,920 |
$11,640
122,535
kWh
|
- | - | - | - | - | - | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,513 | $7,203 |
$1,607
36,520
kWh
|
$2,906
-
kW-mo/yr
|
- | - | - | - | - | |
07 | 2.7234: Use heat pump for space conditioning | $1,731 | $8,247 |
$1,731
18,225
kWh
|
- | - | - | - | - | - | |
08 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $431 | $500 |
$541
11,886
kWh
|
- | - | $(-60.0) | - | $(-50.0) | - | |
TOTAL RECOMMENDED | $584,460 | $522,018 |
$47,627
527,166
kWh
|
$2,906
-
kW-mo/yr
|
$(-15,462.6)
-
MMBtu
|
$(-60.0) | $49,500 | $(-50.0) | $500,000 | ||
TOTAL IMPLEMENTED | $332,298 | $363,271 |
$45,355
497,055
kWh
|
$2,906
-
kW-mo/yr
|
$(-15,462.6)
-
MMBtu
|
- | $49,500 | - | $250,000 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | LPG Savings | Personnel Changes Savings | Primary Raw Material Savings | Ancillary Material Cost Savings | Increase in Production Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs