ITAC Assessment: NL0058
ITAC logo
ITAC Assessment: NL0058
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2021
Principal Product Precision Aircraft Parts
NAICS 336413: Other Aircraft Parts and Auxiliary Equipment Manufacturing
SIC 3728: Aircraft Parts and Auxiliary Equipment, Not Elsewhere Classified
Sales Range $50
M
to 100
M
# of Employees 179
Plant Area 140,000
ft2
Annual Production 6,500,000
units
Production Hrs. Annual 6,240
hrs
Location (State) Nebraska

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $422,441 10,804,130
kWh
Electricity Demand $310,782 14,368
kW-mo/yr
Natural Gas $60,858 7,909
MMBtu
Waste Disposal Costs
Water Usage $18,781 5,403
Tgal
Water Disposal $19,878 5,403
Tgal
TOTAL YEARLY COSTS $832,740
RECOMMENDED SAVINGS* $319,632 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $7,879

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Water Disposal Savings Ancillary Material Cost Savings Increase in Production Savings
01 2.9114: Use solar heat to make electricty $282,217 $1,200,000 $178,393
4,562,480
kWh
$103,824
-
kW-mo/yr
- - -
02 2.7243: Improve air circulation with destratification fans / other methods $24,583 $30,000 $(-1,171.0)
(-29,952)
kWh
$(-1,245.9)
-
kW-mo/yr
- - $27,000
03 2.7142: Utilize higher efficiency lamps and/or ballasts $4,369 $6,060 $1,918
48,952
kWh
$2,007
-
kW-mo/yr
- - -
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $3,510 $2,500 $4,122
105,417
kWh
- - $(-100.0) -
05 3.4155: Meter waste water $2,893 $1,106 - - $2,893
-
Tgal
- -
06 2.4221: Install compressor air intakes in coolest locations $1,164 $728 $1,164
29,768
kWh
- - - -
07 2.7135: Install occupancy sensors $896 $997 $828
21,175
kWh
- - - -
TOTAL RECOMMENDED $319,632 $1,241,391 $185,254
4,737,840
kWh
$104,585
-
kW-mo/yr
$2,893
-
Tgal
$(-100.0) $27,000
TOTAL IMPLEMENTED $7,879 $8,560 $6,040
154,369
kWh
$2,007
-
kW-mo/yr
- $(-100.0) -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Water Disposal Savings Ancillary Material Cost Savings Increase in Production Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs