Assessment Year | 2021 |
---|---|
Principal Product | Precision Aircraft Parts |
NAICS | 336413: Other Aircraft Parts and Auxiliary Equipment Manufacturing |
SIC | 3728: Aircraft Parts and Auxiliary Equipment, Not Elsewhere Classified |
Sales Range | $50 M to 100M |
# of Employees | 179 |
Plant Area |
140,000
ft2
|
Annual Production | 6,500,000
units
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Nebraska |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $422,441 | 10,804,130 |
kWh
|
$0.039 | |
Electricity Demand | $310,782 | 14,368 |
kW-mo/yr
|
$21.63 | |
Natural Gas | $60,858 | 7,909 |
MMBtu
|
$7.70 | |
Waste Disposal Costs | |||||
Water Usage | $18,781 | 5,403 |
Tgal
|
$3.48 | |
Water Disposal | $19,878 | 5,403 |
Tgal
|
$3.68 | |
TOTAL YEARLY COSTS | $832,740 | ||||
RECOMMENDED SAVINGS* | $319,632 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $7,879 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings | Ancillary Material Cost Savings | Increase in Production Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.9114: Use solar heat to make electricty | $282,217 | $1,200,000 |
$178,393
4,562,480
kWh
|
$103,824
-
kW-mo/yr
|
- | - | - | |
02 | 2.7243: Improve air circulation with destratification fans / other methods | $24,583 | $30,000 |
$(-1,171.0)
(-29,952)
kWh
|
$(-1,245.9)
-
kW-mo/yr
|
- | - | $27,000 | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,369 | $6,060 |
$1,918
48,952
kWh
|
$2,007
-
kW-mo/yr
|
- | - | - | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,510 | $2,500 |
$4,122
105,417
kWh
|
- | - | $(-100.0) | - | |
05 | 3.4155: Meter waste water | $2,893 | $1,106 | - | - |
$2,893
-
Tgal
|
- | - | |
06 | 2.4221: Install compressor air intakes in coolest locations | $1,164 | $728 |
$1,164
29,768
kWh
|
- | - | - | - | |
07 | 2.7135: Install occupancy sensors | $896 | $997 |
$828
21,175
kWh
|
- | - | - | - | |
TOTAL RECOMMENDED | $319,632 | $1,241,391 |
$185,254
4,737,840
kWh
|
$104,585
-
kW-mo/yr
|
$2,893
-
Tgal
|
$(-100.0) | $27,000 | ||
TOTAL IMPLEMENTED | $7,879 | $8,560 |
$6,040
154,369
kWh
|
$2,007
-
kW-mo/yr
|
- | $(-100.0) | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings | Ancillary Material Cost Savings | Increase in Production Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs