| Assessment Year | 2018 |
|---|---|
| Principal Product | Treated Wastewater |
| NAICS | 221320: Sewage Treatment Facilities |
| SIC | 4952: Sewerage Systems |
| Sales Range | $1 M to 5M |
| # of Employees | 9 |
| Plant Area |
97,600
ft2
|
| Annual Production | 678,900
Tgal
|
| Production Hrs. Annual | 8,760
hrs
|
| Location (State) | Nebraska |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $71,033 | 1,775,825 |
kWh
|
$0.040 |
| Electricity Demand | $86,636 | 4,126 |
kW-mo/yr
|
$21.00 |
| Electricity Fees | $25,063 | - |
|
- |
| TOTAL YEARLY COSTS | $182,732 | |||
| RECOMMENDED SAVINGS* | $53,279 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $1,010 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $47,523 | $155,000 |
$26,859
718,320
kWh
|
$20,664
-
kW-mo/yr
|
- | |
| 02 | 4.651: Install back-up equipment | $4,746 | $2,010 |
$196
4,900
kWh
|
- | $4,550 | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,010 | $5,620 |
$436
10,900
kWh
|
- | $574 | |
| TOTAL RECOMMENDED | $53,279 | $162,630 |
$27,491
734,120
kWh
|
$20,664
-
kW-mo/yr
|
$5,124 | ||
| TOTAL IMPLEMENTED | $1,010 | $5,620 |
$436
10,900
kWh
|
- | $574 | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs