Assessment Year | 2017 |
---|---|
Principal Product | Injection Molded Plastics |
NAICS | 326199: All Other Plastics Product Manufacturing |
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $5 M to 10M |
# of Employees | 45 |
Plant Area |
43,200
ft2
|
Annual Production | 1,000,000
units
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Nebraska |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $89,067 | 2,606,805 |
kWh
|
$0.034 | |
Electricity Demand | $70,843 | 6,358 |
kW-mo/yr
|
$11.14 | |
Electricity Fees | $10,964 | - |
|
- | |
LPG | $4,941 | 399 |
MMBtu
|
$12.39 | |
Waste Disposal Costs | |||||
Water Usage | $2,791 | 1,355 |
Tgal
|
$2.06 | |
Water Disposal | $4,792 | 1,355 |
Tgal
|
$3.54 | |
TOTAL YEARLY COSTS | $183,397 | ||||
RECOMMENDED SAVINGS* | $17,162 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $12,460 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings |
---|---|---|---|---|---|---|---|
01 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $7,477 | $136 | - |
$7,477
-
kW-mo/yr
|
- | |
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $3,200 | - |
$3,200
94,300
kWh
|
- | - | |
03 | 3.4116: Meter recycled water (to reduce sewer charges) | $3,183 | $250 | - | - |
$3,183
-
Tgal
|
|
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,638 | $9,825 |
$1,076
31,648
kWh
|
$562
-
kW-mo/yr
|
- | |
05 | 2.7135: Install occupancy sensors | $920 | $980 |
$920
27,048
kWh
|
- | - | |
06 | 2.7243: Improve air circulation with destratification fans / other methods | $582 | $2,100 |
$365
9,600
kWh
|
$217
-
kW-mo/yr
|
- | |
07 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $163 | $157 |
$100
2,936
kWh
|
$63
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $17,162 | $13,448 |
$5,660
165,532
kWh
|
$8,318
-
kW-mo/yr
|
$3,183
-
Tgal
|
||
TOTAL IMPLEMENTED | $12,460 | $10,368 |
$1,176
34,584
kWh
|
$8,102
-
kW-mo/yr
|
$3,183
-
Tgal
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs