Assessment Year 2000
Principal Product Sttel Drawer Slides
NAICS
n/a
SIC 3441: Fabricated Structural Metal
Sales Range $10
M
to 50
M
# of Employees 270
Plant Area 160,000
ft2
Annual Production 9,000,000
pieces
Production Hrs. Annual 5,000
hrs
Location (State) Indiana

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $126,372 4,184,643
kWh
Electricity Demand $104,878 10,915
kW-mo/yr
Electricity Fees $(-11,059.0) -
Natural Gas $54,061 12,580
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $7,172 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $4,855

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Water Disposal Savings Personnel Changes Savings Primary Raw Material Savings Ancillary Material Cost Savings Water Consumption Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $2,863 $9,787 $1,344
45,428
kWh
$1,519
-
kW-mo/yr
- - - - - -
02 2.7135: Install occupancy sensors $681 $1,600 $338
11,430
kWh
$343
-
kW-mo/yr
- - - - - -
03 2.7142: Utilize higher efficiency lamps and/or ballasts $394 $420 $87
2,931
kWh
$39
-
kW-mo/yr
- - $175 - $93 -
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $917 $50 $358
12,016
kWh
$159
-
kW-mo/yr
- - $400 - - -
05 2.7134: Use photocell controls $92 $300 $31
1,172
kWh
$61
-
kW-mo/yr
- - - - - -
06 2.7111: Reduce illumination to minimum necessary levels $302 $90 $103
3,517
kWh
$199
-
kW-mo/yr
- - - - - -
07 3.3131: Use evaporation to concentrate material $746 $250 - - - $746
-
Tgal
- - - -
08 2.8121: Apply for tax-free status for energy purchases $210 $200 - - $210 - - - - -
09 3.1244: Reduce solution drag-out to prevent solution loss $967 - - - - $222
-
Tgal
- $583 - $162
-
Tgal
TOTAL RECOMMENDED $7,172 $12,697 $2,261
76,494
kWh
$2,320
-
kW-mo/yr
$210 $968
-
Tgal
$575 $583 $93 $162
-
Tgal
TOTAL IMPLEMENTED $4,855 $11,827 $2,174
73,563
kWh
$2,281
-
kW-mo/yr
- - $400 - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Water Disposal Savings Personnel Changes Savings Primary Raw Material Savings Ancillary Material Cost Savings Water Consumption Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs