| Assessment Year | 1998 |
|---|---|
| Principal Product | hand towels |
| NAICS |
n/a
|
| SIC | 2621: Paper Mills |
| Sales Range | $10 M to 50M |
| # of Employees | 78 |
| Plant Area |
131,000
ft2
|
| Annual Production | 30,000
ton
|
| Production Hrs. Annual | 8,400
hrs
|
| Location (State) | Indiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $1,201,819 | 23,897,421 |
kWh
|
$0.050 |
| Electricity Demand | $388,477 | 38,937 |
kW-mo/yr
|
$9.98 |
| Electricity Fees | $(-165,861.0) | - |
|
- |
| Natural Gas | $1,094,232 | 293,967 |
MMBtu
|
$3.72 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $27,467 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,728 | $10,560 | n/a |
$2,084
41,032
kWh
|
$644
-
kW-mo/yr
|
- | - | - | - |
| 02 | 2.4131: Size electric motors for peak operating efficiency | $2,180 | $20,614 | n/a |
$467
8,792
kWh
|
$124
-
kW-mo/yr
|
- | - | - | $1,589 |
| 03 | 2.7135: Install occupancy sensors | $924 | $750 | n/a |
$719
12,603
kWh
|
$205
-
kW-mo/yr
|
- | - | - | - |
| 04 | 2.4321: Upgrade obsolete equipment | $207 | $930 | n/a |
$303
6,155
kWh
|
- | - |
$(-96.0)
-
MMBtu
|
- | - |
| 05 | 2.7111: Reduce illumination to minimum necessary levels | $5,863 | $3,690 | n/a |
$2,479
47,186
kWh
|
$654
-
kW-mo/yr
|
- | - | - | $2,730 |
| 06 | 4.222: Purchase re-conditioned material instead of new | $3,629 | $97,088 | n/a |
$2,868
54,513
kWh
|
$761
-
kW-mo/yr
|
- | - | - | - |
| 07 | 2.8112: Combine utility meters | $2,283 | $1,250 | n/a | - | - | $1,683 | - | $600 | - |
| 08 | 2.3212: Optimize plant power factor | $9,653 | $11,700 | n/a | - |
$9,653
-
kW-mo/yr
|
- | - | - | - |
| TOTAL RECOMMENDED | $27,467 | $146,582 |
$8,920
170,281
kWh
|
$12,041
-
kW-mo/yr
|
$1,683 |
$(-96.0)
-
MMBtu
|
$600 | $4,319 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs