ITAC Assessment: ND0314
ITAC logo
ITAC Assessment: ND0314
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1998
Principal Product hand towels
NAICS
n/a
SIC 2621: Paper Mills
Sales Range $10
M
to 50
M
# of Employees 78
Plant Area 131,000
ft2
Annual Production 30,000
ton
Production Hrs. Annual 8,400
hrs
Location (State) Indiana

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $1,201,819 23,897,421
kWh
Electricity Demand $388,477 38,937
kW-mo/yr
Electricity Fees $(-165,861.0) -
Natural Gas $1,094,232 293,967
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $27,467 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings Personnel Changes Savings One-time Revenue or Avoided Cost Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $2,728 $10,560 n/a $2,084
41,032
kWh
$644
-
kW-mo/yr
- - - -
02 2.4131: Size electric motors for peak operating efficiency $2,180 $20,614 n/a $467
8,792
kWh
$124
-
kW-mo/yr
- - - $1,589
03 2.7135: Install occupancy sensors $924 $750 n/a $719
12,603
kWh
$205
-
kW-mo/yr
- - - -
04 2.4321: Upgrade obsolete equipment $207 $930 n/a $303
6,155
kWh
- - $(-96.0)
-
MMBtu
- -
05 2.7111: Reduce illumination to minimum necessary levels $5,863 $3,690 n/a $2,479
47,186
kWh
$654
-
kW-mo/yr
- - - $2,730
06 4.222: Purchase re-conditioned material instead of new $3,629 $97,088 n/a $2,868
54,513
kWh
$761
-
kW-mo/yr
- - - -
07 2.8112: Combine utility meters $2,283 $1,250 n/a - - $1,683 - $600 -
08 2.3212: Optimize plant power factor $9,653 $11,700 n/a - $9,653
-
kW-mo/yr
- - - -
TOTAL RECOMMENDED $27,467 $146,582 $8,920
170,281
kWh
$12,041
-
kW-mo/yr
$1,683 $(-96.0)
-
MMBtu
$600 $4,319
TOTAL IMPLEMENTED - - - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings Personnel Changes Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs