Assessment Year 2001
Principal Product Assembly of Drive Axels
NAICS
n/a
SIC 3799: Transportation Equipment, Not Elsewhere Classified
Sales Range $50
M
to 100
M
# of Employees 245
Plant Area 160,590
ft2
Annual Production 5,000
pieces
Production Hrs. Annual 5,100
hrs
Location (State) Illinois

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $116,799 2,899,462
kWh
Electricity Demand $103,389 8,368
kW-mo/yr
Electricity Fees $24,737 -
Natural Gas $38,919 7,463
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $630,248 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $33,796

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings Solid Waste (non-haz) Savings Personnel Changes Savings Administrative Changes Savings Ancillary Material Cost Savings
01 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,962 $1,500 $1,148
27,989
kWh
$814
-
kW-mo/yr
- - - - - -
02 2.7142: Utilize higher efficiency lamps and/or ballasts $26,503 $92,040 n/a $15,527
378,706
kWh
$10,976
-
kW-mo/yr
- - - - - -
03 2.7142: Utilize higher efficiency lamps and/or ballasts $522 $1,677 $110
2,681
kWh
$45
-
kW-mo/yr
- - - $248 - $119
04 2.7142: Utilize higher efficiency lamps and/or ballasts $1,569 $7,461 $903
22,020
kWh
$640
-
kW-mo/yr
- - - $26 - -
05 2.7135: Install occupancy sensors $1,359 $2,516 $1,196
29,163
kWh
$163
-
kW-mo/yr
- - - - - -
06 2.4133: Use most efficient type of electric motors $369 $1,551 $138
3,367
kWh
$231
-
kW-mo/yr
- - - - - -
07 2.2511: Insulate bare equipment $222 $832 - - - $222
-
MMBtu
- - - -
08 2.2511: Insulate bare equipment $652 $2,670 - - - $652
-
MMBtu
- - - -
09 2.2511: Insulate bare equipment $128 $370 - - - $128
-
MMBtu
- - - -
10 2.3132: Recharge batteries on during off-peak demand periods $162 - - - $162 - - - - -
11 3.5316: Contract a wood pallet recycling company $28,000 $5,300 - - - - $28,000
-
lb
- - -
12 4.447: Automate payroll system $84,800 $6,670 - - - - - $69,800 $15,000 -
13 4.426: Modify workload $484,000 $66,100 - - - - - $480,000 $4,000 -
TOTAL RECOMMENDED $630,248 $188,687 $19,022
463,926
kWh
$12,869
-
kW-mo/yr
$162 $1,002
-
MMBtu
$28,000
-
lb
$550,074 $19,000 $119
TOTAL IMPLEMENTED $33,796 $19,286 $3,357
81,853
kWh
$1,662
-
kW-mo/yr
$162 $222
-
MMBtu
$28,000
-
lb
$274 - $119
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings Solid Waste (non-haz) Savings Personnel Changes Savings Administrative Changes Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs