ITAC Assessment: ND0240
ITAC logo
ITAC Assessment: ND0240
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1996
Principal Product Fasteners
NAICS
n/a
SIC 3452: Bolts, Nuts, Screws, Rivets, and Washers
Sales Range $10
M
to 50
M
# of Employees 205
Plant Area 145,600
ft2
Annual Production 960,000,000
pieces
Production Hrs. Annual 7,200
hrs
Location (State) Indiana

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $161,100 7,157,093
kWh
Electricity Demand $111,396 15,116
kW-mo/yr
Electricity Fees $(-3,342.0) -
Natural Gas $70,927 22,133
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $34,244 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $30,883

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Administrative Changes Savings
01 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $2,400 $750 $2,400
64,185
kWh
- - -
02 2.4133: Use most efficient type of electric motors $23,589 $18,280 $16,637
444,900
kWh
$6,952
-
kW-mo/yr
- -
03 2.7142: Utilize higher efficiency lamps and/or ballasts $544 $1,100 $384
10,258
kWh
$160
-
kW-mo/yr
- -
04 2.8123: Pay utility bills on time $15 - - - $15 -
05 2.8121: Apply for tax-free status for energy purchases $132 $250 - - $132 -
06 2.6218: Turn off equipment when not in use $270 $1,008 $270
7,327
kWh
- - -
07 2.3212: Optimize plant power factor $7,294 $12,852 - - - $7,294
TOTAL RECOMMENDED $34,244 $34,240 $19,691
526,670
kWh
$7,112
-
kW-mo/yr
$147 $7,294
TOTAL IMPLEMENTED $30,883 $31,132 $16,637
444,900
kWh
$6,952
-
kW-mo/yr
- $7,294
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs