| Assessment Year | 1995 |
|---|---|
| Principal Product | vacumn formed plastic |
| NAICS |
n/a
|
| SIC | 3089: Plastics Products, Not Elsewhere Classified |
| Sales Range | $5 M to 10M |
| # of Employees | 130 |
| Plant Area |
130,000
ft2
|
| Annual Production | 6,000,000
lb
|
| Production Hrs. Annual | 5,600
hrs
|
| Location (State) | Michigan |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $199,733 | 2,230,363 |
kWh
|
$0.090 |
| Natural Gas | $35,532 | 7,910 |
MMBtu
|
$4.49 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $20,474 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $18,880 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Solid Waste (non-haz) Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $5,253 | $1,120 |
$5,253
68,288
kWh
|
- | |
| 02 | 2.4133: Use most efficient type of electric motors | $4,160 | $6,280 |
$4,160
54,513
kWh
|
- | |
| 03 | 2.4221: Install compressor air intakes in coolest locations | $1,594 | $300 |
$1,594
20,809
kWh
|
- | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $567 | $358 |
$567
7,327
kWh
|
- | |
| 05 | 3.5212: Regrind, reuse, or sell scrap plastic parts | $8,900 | $15,020 | - |
$8,900
-
lb
|
|
| TOTAL RECOMMENDED | $20,474 | $23,078 |
$11,574
150,937
kWh
|
$8,900
-
lb
|
||
| TOTAL IMPLEMENTED | $18,880 | $22,778 |
$9,980
130,128
kWh
|
$8,900
-
lb
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs