| Assessment Year | 1995 |
|---|---|
| Principal Product | Popcorn |
| NAICS |
n/a
|
| SIC | 2096: Potato Chips, Corn Chips, and Similar Snacks |
| Sales Range | $50 M to 100M |
| # of Employees | 200 |
| Plant Area |
300,000
ft2
|
| Annual Production | 200,000,000
lb
|
| Production Hrs. Annual | 7,008
hrs
|
| Location (State) | Indiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $495,207 | 8,398,593 |
kWh
|
$0.059 |
| Natural Gas | $46,021 | 10,052 |
MMBtu
|
$4.58 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $22,376 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $16,075 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $14,560 | $38,000 |
$14,560
250,293
kWh
|
|
| 02 | 2.7135: Install occupancy sensors | $3,594 | $2,000 |
$3,594
69,168
kWh
|
|
| 03 | 2.3212: Optimize plant power factor | $1,900 | $3,105 |
$1,900
-
kWh
|
|
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,300 | $240 |
$1,300
25,205
kWh
|
|
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $807 | $478 |
$807
15,533
kWh
|
|
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $215 | $1,090 |
$215
4,103
kWh
|
|
| TOTAL RECOMMENDED | $22,376 | $44,913 |
$22,376
364,302
kWh
|
||
| TOTAL IMPLEMENTED | $16,075 | $39,330 |
$16,075
279,601
kWh
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs