Assessment Year | 1994 |
---|---|
Principal Product | Plastic Injection Moldings |
NAICS |
n/a
|
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $50 M to 100M |
# of Employees | 480 |
Plant Area |
42,400
ft2
|
Annual Production | 26,000,000
pieces
|
Production Hrs. Annual | 8,736
hrs
|
Location (State) | Michigan |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,466,843 | 28,165,006 |
kWh
|
$0.052 |
Natural Gas | $28,696 | 5,807 |
MMBtu
|
$4.94 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $4,169 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,340 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|
01 | 2.6212: Turn off equipment during breaks, reduce operating time | $2,403 | $3,520 |
$2,403
46,307
kWh
|
- | |
02 | 2.7111: Reduce illumination to minimum necessary levels | $533 | $53 |
$533
10,258
kWh
|
- | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $426 | $329 |
$426
8,206
kWh
|
- | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $296 | $480 |
$296
5,569
kWh
|
- | |
05 | 2.8114: Change rate schedules or other changes in utility service | $511 | $50 | - | $511 | |
TOTAL RECOMMENDED | $4,169 | $4,432 |
$3,658
70,340
kWh
|
$511 | ||
TOTAL IMPLEMENTED | $3,340 | $3,899 |
$2,829
54,513
kWh
|
$511 |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs