| Assessment Year | 1994 |
|---|---|
| Principal Product | aluminum closures |
| NAICS |
n/a
|
| SIC | 3466: Crowns and Closures |
| Sales Range | $10 M to 50M |
| # of Employees | 375 |
| Plant Area |
460,000
ft2
|
| Annual Production | 3,000,000,000
pieces
|
| Production Hrs. Annual | 6,000
hrs
|
| Location (State) | Indiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $614,064 | 19,146,835 |
kWh
|
$0.032 |
| Natural Gas | $497,670 | 164,014 |
MMBtu
|
$3.03 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $54,796 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $36,355 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $26,134 | $33,690 |
$26,134
591,442
kWh
|
|
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $9,875 | $6,890 |
$9,875
223,623
kWh
|
|
| 03 | 2.7135: Install occupancy sensors | $3,327 | $3,200 |
$3,327
75,322
kWh
|
|
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $385 | $650 |
$385
8,792
kWh
|
|
| 05 | 2.7122: Disconnect ballasts | $346 | $955 |
$346
7,913
kWh
|
|
| 06 | 2.7111: Reduce illumination to minimum necessary levels | $10,653 | $500 |
$10,653
241,208
kWh
|
|
| 07 | 2.2614: Use cooling tower or economizer to replace chiller cooling | $4,076 | $18,000 |
$4,076
92,321
kWh
|
|
| TOTAL RECOMMENDED | $54,796 | $63,885 |
$54,796
1,240,621
kWh
|
||
| TOTAL IMPLEMENTED | $36,355 | $41,535 |
$36,355
822,978
kWh
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs