Assessment Year | 1994 |
---|---|
Principal Product | Cast Aluminum Wheels |
NAICS |
n/a
|
SIC | 3714: Motor Vehicle Parts and Accessories |
Sales Range | $10 M to 50M |
# of Employees | 120 |
Plant Area |
58,000
ft2
|
Annual Production | 350,000
pieces
|
Production Hrs. Annual | 5,000
hrs
|
Location (State) | Indiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $319,491 | 7,021,395 |
kWh
|
$0.046 |
Natural Gas | $173,804 | 44,759 |
MMBtu
|
$3.88 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $37,369 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $18,448 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $13,218 | $10,190 |
$13,218
319,754
kWh
|
- | |
02 | 2.3212: Optimize plant power factor | $4,736 | $3,046 |
$4,736
-
kWh
|
- | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,039 | $1,365 |
$1,039
25,205
kWh
|
- | |
04 | 2.6218: Turn off equipment when not in use | $494 | - |
$494
12,016
kWh
|
- | |
05 | 2.2514: Cover open tanks | $276 | $642 | - |
$276
-
MMBtu
|
|
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $110 | $320 |
$110
2,638
kWh
|
- | |
07 | 2.7111: Reduce illumination to minimum necessary levels | $6,241 | $300 |
$6,241
150,938
kWh
|
- | |
08 | 2.2221: Use immersion heating in tanks, melting pots, etc | $11,255 | $26,000 | - |
$11,255
-
MMBtu
|
|
TOTAL RECOMMENDED | $37,369 | $41,863 |
$25,838
510,551
kWh
|
$11,531
-
MMBtu
|
||
TOTAL IMPLEMENTED | $18,448 | $13,236 |
$18,448
331,770
kWh
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs