Assessment Year | 1994 |
---|---|
Principal Product | Pressure controls |
NAICS |
n/a
|
SIC | 3823: Industrial Instruments for Measurement, Display, and Control of Process Variables; and Related Products |
Sales Range | $5 M to 10M |
# of Employees | 90 |
Plant Area |
40,000
ft2
|
Annual Production | 65,000
pieces
|
Production Hrs. Annual | 2,210
hrs
|
Location (State) | Indiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $48,201 | 504,982 |
kWh
|
$0.095 |
Natural Gas | $9,809 | 1,848 |
MMBtu
|
$5.31 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $7,076 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $4,992 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|
01 | 2.8121: Apply for tax-free status for energy purchases | $1,944 | $194 |
$1,944
20,516
kWh
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $921 | $3,770 |
$921
9,672
kWh
|
- | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,748 | $250 | - | $2,748 | |
04 | 2.7111: Reduce illumination to minimum necessary levels | $813 | $90 |
$813
8,499
kWh
|
- | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $157 | $140 |
$157
1,758
kWh
|
- | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $350 | $150 |
$350
3,810
kWh
|
- | |
07 | 2.4133: Use most efficient type of electric motors | $143 | $110 |
$143
1,465
kWh
|
- | |
TOTAL RECOMMENDED | $7,076 | $4,704 |
$4,328
45,720
kWh
|
$2,748 | ||
TOTAL IMPLEMENTED | $4,992 | $694 |
$2,244
23,739
kWh
|
$2,748 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs