| Assessment Year | 1993 |
|---|---|
| Principal Product | Reinforced Fiberglass Electrical Box |
| NAICS |
n/a
|
| SIC | 3069: Fabricated Rubber Products, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 225 |
| Plant Area |
195,000
ft2
|
| Annual Production | 36,000,000
pieces
|
| Production Hrs. Annual | 6,000
hrs
|
| Location (State) | Ohio |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $396,526 | 8,868,113 |
kWh
|
$0.045 |
| Natural Gas | $13,292 | 2,536 |
MMBtu
|
$5.24 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $6,261 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $4,164 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $3,033 | $3,875 |
$3,033
67,702
kWh
|
|
| 02 | 2.3212: Optimize plant power factor | $1,428 | $4,920 |
$1,428
-
kWh
|
|
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,131 | $1,061 |
$1,131
25,205
kWh
|
|
| 04 | 2.3212: Optimize plant power factor | $507 | $810 |
$507
-
kWh
|
|
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $162 | $450 |
$162
3,517
kWh
|
|
| TOTAL RECOMMENDED | $6,261 | $11,116 |
$6,261
96,424
kWh
|
||
| TOTAL IMPLEMENTED | $4,164 | $4,936 |
$4,164
92,907
kWh
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs