| Assessment Year | 1992 |
|---|---|
| Principal Product | SITE FURNISHINGS |
| NAICS |
n/a
|
| SIC | 2531: Public Building and Related Furniture |
| Sales Range | $10 M to 50M |
| # of Employees | 86 |
| Plant Area |
n/a
|
| Annual Production | 0
units
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | Michigan |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $66,763 | 886,870 |
kWh
|
$0.075 |
| Natural Gas | $36,934 | 8,342 |
MMBtu
|
$4.43 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $9,240 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $1,739 | $12,780 |
$1,739
23,154
kWh
|
- | - | |
| 02 | 2.4221: Install compressor air intakes in coolest locations | $2,594 | $500 |
$2,594
34,291
kWh
|
- | - | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,927 | $1,119 |
$2,178
29,015
kWh
|
- | $(-251.0) | |
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,537 | $200 |
$2,537
33,705
kWh
|
- | - | |
| 05 | 2.1233: Analyze flue gas for proper air/fuel ratio | $443 | $500 | - |
$443
-
MMBtu
|
- | |
| TOTAL RECOMMENDED | $9,240 | $15,099 |
$9,048
120,165
kWh
|
$443
-
MMBtu
|
$(-251.0) | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs