| Assessment Year | 1991 |
|---|---|
| Principal Product | VAN TOPS & ACCESSORIES |
| NAICS |
n/a
|
| SIC | 3714: Motor Vehicle Parts and Accessories |
| Sales Range | $5 M to 10M |
| # of Employees | 103 |
| Plant Area |
n/a
|
| Annual Production | 24,000
pieces
|
| Production Hrs. Annual | 2,145
hrs
|
| Location (State) | Indiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $86,952 | 883,646 |
kWh
|
$0.098 |
| Natural Gas | $67,163 | 14,554 |
MMBtu
|
$4.61 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $9,737 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7492: Use proper thickness of insulation on building envelope | $5,106 | $23,848 | n/a |
$2,407
23,154
kWh
|
$2,699
-
MMBtu
|
- |
| 02 | 2.7492: Use proper thickness of insulation on building envelope | $2,926 | $11,560 | n/a |
$1,704
16,413
kWh
|
$1,222
-
MMBtu
|
- |
| 03 | 2.4133: Use most efficient type of electric motors | $589 | $7,230 | n/a |
$589
5,862
kWh
|
- | - |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $249 | $853 | n/a |
$548
5,569
kWh
|
- | $(-299.0) |
| 05 | 2.8121: Apply for tax-free status for energy purchases | $867 | $250 | n/a |
$867
-
kWh
|
- | - |
| TOTAL RECOMMENDED | $9,737 | $43,741 |
$6,115
50,998
kWh
|
$3,921
-
MMBtu
|
$(-299.0) | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs