Assessment Year 2021
Principal Product Dyed Goods
NAICS 313310: Textile and Fabric Finishing Mills
SIC 2262: Finishers of Broadwoven Fabrics of Manmade Fiber and Silk
Sales Range $1
M
to 5
M
# of Employees 80
Plant Area 150,000
ft2
Annual Production 3,000,000
lb
Production Hrs. Annual 4,000
hrs
Location (State) North Carolina

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $116,460 1,873,849
kWh
Electricity Demand $105,454 9,719
kW-mo/yr
Natural Gas $239,314 52,311
MMBtu
Waste Disposal Costs
Water Usage $262,367 32,857
Tgal
TOTAL YEARLY COSTS $723,595
RECOMMENDED SAVINGS* $127,788 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Water Usage Savings Ancillary Material Cost Savings
01 2.1233: Analyze flue gas for proper air/fuel ratio $8,055 $3,000 - - $8,055
-
MMBtu
- -
02 2.2449: Recover heat from exhausted steam, hot air or hot water $23,051 $15,000 - - $26,051
-
MMBtu
- $(-3,000.0)
03 2.4231: Reduce the pressure of compressed air to the minimum required $1,619 $5,000 $1,063
17,083
kWh
$556
-
kW-mo/yr
- - -
04 3.4159: Replace treated water with well / surface water $92,941 $500 $(-928.0)
(-14,914)
kWh
$(-485.0)
-
kW-mo/yr
- $94,354
-
Tgal
-
05 2.7142: Utilize higher efficiency lamps and/or ballasts $1,952 $4,258 $1,952
31,383
kWh
- - - -
06 2.4231: Reduce the pressure of compressed air to the minimum required $170 $400 $170
2,730
kWh
- - - -
TOTAL RECOMMENDED $127,788 $28,158 $2,257
36,282
kWh
$71
-
kW-mo/yr
$34,106
-
MMBtu
$94,354
-
Tgal
$(-3,000.0)
TOTAL IMPLEMENTED - - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Water Usage Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs