| Assessment Year | 2019 |
|---|---|
| Principal Product | Plastic mesh bags |
| NAICS | 326199: All Other Plastics Product Manufacturing |
| SIC | 3069: Fabricated Rubber Products, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 80 |
| Plant Area |
44,000
ft2
|
| Annual Production | 9,000,000
lb
|
| Production Hrs. Annual | 6,000
hrs
|
| Location (State) | Virginia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $429,510 | 5,915,800 |
kWh
|
$0.073 |
| Electricity Demand | $54,918 | 12,922 |
kW-mo/yr
|
$4.25 |
| Electricity Fees | $297 | - |
|
- |
| Natural Gas | $20,706 | 2,859 |
MMBtu
|
$7.24 |
| TOTAL YEARLY COSTS | $505,431 | |||
| RECOMMENDED SAVINGS* | $53,044 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $29,143 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,164 | $120 |
$1,042
14,350
kWh
|
$122
-
kW-mo/yr
|
- | |
| 02 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $18,554 | $21,000 |
$26,572
366,000
kWh
|
$3,111
-
kW-mo/yr
|
$(-11,129.0)
-
MMBtu
|
|
| 03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $29,143 | $35,000 |
$26,101
359,520
kWh
|
$3,042
-
kW-mo/yr
|
- | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,183 | $16,246 |
$3,648
50,245
kWh
|
$535
-
kW-mo/yr
|
- | |
| TOTAL RECOMMENDED | $53,044 | $72,366 |
$57,363
790,115
kWh
|
$6,810
-
kW-mo/yr
|
$(-11,129.0)
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $29,143 | $35,000 |
$26,101
359,520
kWh
|
$3,042
-
kW-mo/yr
|
- | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs