Assessment Year 2018
Principal Product Yarn
NAICS 313110: Fiber, Yarn, and Thread Mills
SIC 2281: Yarn Spinning Mills
Sales Range $10
M
to 50
M
# of Employees 100
Plant Area 140,000
ft2
Annual Production 15,000,000
lb
Production Hrs. Annual 6,000
hrs
Location (State) North Carolina

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $469,008 12,592,500
kWh
Electricity Demand $274,760 23,925
kW-mo/yr
Waste Disposal Costs
Water Usage $7,578 3,626
Tgal
Water Disposal $7,578 3,626
Tgal
TOTAL YEARLY COSTS $758,924
RECOMMENDED SAVINGS* $22,511 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $2,991

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Water Usage Savings Water Disposal Savings Personnel Changes Savings Ancillary Material Cost Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $10,207 $42,729 $5,898
158,535
kWh
$4,309
-
kW-mo/yr
- - - -
02 2.7135: Install occupancy sensors $190 $350 $190
5,109
kWh
- - - - -
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $2,801 $200 $1,942
52,218
kWh
$1,090
-
kW-mo/yr
- - $(-120.0) $(-111.0)
04 2.4239: Eliminate or reduce compressed air usage $658 $2,700 $658
17,675
kWh
- - - - -
05 2.4231: Reduce the pressure of compressed air to the minimum required $582 $100 $373
10,020
kWh
$209
-
kW-mo/yr
- - - -
06 3.4116: Meter recycled water (to reduce sewer charges) $5,876 $2,450 - - - $5,876
-
Tgal
- -
07 3.4115: Recover and reuse cooling water $2,197 $3,000 - - $1,098
-
Tgal
$1,099
-
Tgal
- -
TOTAL RECOMMENDED $22,511 $51,529 $9,061
243,557
kWh
$5,608
-
kW-mo/yr
$1,098
-
Tgal
$6,975
-
Tgal
$(-120.0) $(-111.0)
TOTAL IMPLEMENTED $2,991 $550 $2,132
57,327
kWh
$1,090
-
kW-mo/yr
- - $(-120.0) $(-111.0)
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Water Usage Savings Water Disposal Savings Personnel Changes Savings Ancillary Material Cost Savings