ITAC Assessment: NC0595
ITAC logo
ITAC Assessment: NC0595
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2017
Principal Product Socks
NAICS 315110: Hosiery and Sock Mills
SIC 2252: Hosiery, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 185
Plant Area 130,000
ft2
Annual Production 6,300,000
pieces
Production Hrs. Annual 6,000
hrs
Location (State) North Carolina

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $212,284 4,822,200
kWh
Electricity Demand $122,915 10,401
kW-mo/yr
Natural Gas $107,000 10,693
MMBtu
TOTAL YEARLY COSTS $442,199
RECOMMENDED SAVINGS* $35,132 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $4,787

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Personnel Changes Savings Ancillary Material Cost Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $29,435 $144,553 $18,325
411,798
kWh
$11,110
-
kW-mo/yr
- - -
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $896 $100 $852
19,156
kWh
$444
-
kW-mo/yr
- $(-200.0) $(-200.0)
03 2.7228: Avoid introducing hot, humid, or dirty air into hvac system $375 $552 $245
5,500
kWh
$130
-
kW-mo/yr
- - -
04 2.2521: Isolate steam lines to avoid heating air conditioned areas $3,516 $400 $761
17,100
kWh
$405
-
kW-mo/yr
$2,350
-
MMBtu
- -
05 2.2437: Recover waste heat from equipment $910 $2,000 - - $910
-
MMBtu
- -
TOTAL RECOMMENDED $35,132 $147,605 $20,183
453,554
kWh
$12,089
-
kW-mo/yr
$3,260
-
MMBtu
$(-200.0) $(-200.0)
TOTAL IMPLEMENTED $4,787 $1,052 $1,858
41,756
kWh
$979
-
kW-mo/yr
$2,350
-
MMBtu
$(-200.0) $(-200.0)
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs