Assessment Year 2016
Principal Product Testing equipment
NAICS 334516: Analytical Laboratory Instrument Manufacturing
SIC 3826: Laboratory Analytical Instruments
Sales Range $10
M
to 50
M
# of Employees 100
Plant Area 100,000
ft2
Annual Production 1,000
pieces
Production Hrs. Annual 3,060
hrs
Location (State) North Carolina

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $71,972 1,112,400
kWh
Electricity Demand $21,194 4,752
kW-mo/yr
TOTAL YEARLY COSTS $93,166
RECOMMENDED SAVINGS* $27,261 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $23,615

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Personnel Changes Savings Ancillary Material Cost Savings
01 2.8118: Check for accuracy of utility / power meters $2,610 $100 - $2,610
-
kW-mo/yr
- -
02 2.7142: Utilize higher efficiency lamps and/or ballasts $19,606 $76,556 $11,986
185,251
kWh
$3,459
-
kW-mo/yr
- $4,161
03 2.7142: Utilize higher efficiency lamps and/or ballasts $3,685 $13,453 $3,140
48,537
kWh
- - $545
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $105 $200 $358
5,539
kWh
$97
-
kW-mo/yr
$(-150.0) $(-200.0)
05 2.4231: Reduce the pressure of compressed air to the minimum required $219 $100 $172
2,665
kWh
$47
-
kW-mo/yr
- -
06 2.4239: Eliminate or reduce compressed air usage $418 $75 $418
6,454
kWh
- - -
07 2.7142: Utilize higher efficiency lamps and/or ballasts $618 $160 $277
4,275
kWh
$26
-
kW-mo/yr
- $315
TOTAL RECOMMENDED $27,261 $90,644 $16,351
252,721
kWh
$6,239
-
kW-mo/yr
$(-150.0) $4,821
TOTAL IMPLEMENTED $23,615 $90,309 $15,656
241,992
kWh
$3,603
-
kW-mo/yr
$(-150.0) $4,506
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Personnel Changes Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs