ITAC Assessment: NC0475
ITAC logo
ITAC Assessment: NC0475
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2013
Principal Product Water meters
NAICS 334514: Totalizing Fluid Meter and Counting Device Manufacturing
SIC 3824: Totalizing Fluid Meters and Counting Devices
Sales Range $10
M
to 50
M
# of Employees 175
Plant Area 126,000
ft2
Annual Production 10
units
Production Hrs. Annual 7,200
hrs
Location (State) North Carolina

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $280,561 5,707,760
kWh
Electricity Demand $73,727 10,945
kW-mo/yr
Electricity Fees $726 -
Natural Gas $16,186 1,914
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $68,198 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Personnel Changes Savings Ancillary Material Cost Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $28,801 $48,075 $23,919
486,662
kWh
$5,467
-
kW-mo/yr
- - $(-585.0)
02 2.7135: Install occupancy sensors $9,597 $5,600 $9,338
189,997
kWh
$259
-
kW-mo/yr
- - -
03 2.7142: Utilize higher efficiency lamps and/or ballasts $975 $1,124 $332
6,760
kWh
$62
-
kW-mo/yr
- - $581
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $620 $100 $1,188
24,170
kWh
$272
-
kW-mo/yr
- $(-600.0) $(-240.0)
05 2.2437: Recover waste heat from equipment $11,988 $4,750 - - $11,988
-
MMBtu
- -
06 2.5123: Reduce fluid flow rates $16,217 $25,000 $13,200
268,560
kWh
$3,017
-
kW-mo/yr
- - -
TOTAL RECOMMENDED $68,198 $84,649 $47,977
976,149
kWh
$9,077
-
kW-mo/yr
$11,988
-
MMBtu
$(-600.0) $(-244.0)
TOTAL IMPLEMENTED - - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Personnel Changes Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs