| Assessment Year | 2012 |
|---|---|
| Principal Product | Upholstered furniture |
| NAICS | 337121: Upholstered Household Furniture Manufacturing |
| SIC | 2512: Wood Household Furniture, Upholstered |
| Sales Range | $5 M to 10M |
| # of Employees | 100 |
| Plant Area |
454,422
ft2
|
| Annual Production | 36,000
pieces
|
| Production Hrs. Annual | 2,000
hrs
|
| Location (State) | North Carolina |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $111,042 | 1,756,770 |
kWh
|
$0.063 |
| Electricity Demand | $34,708 | 8,817 |
kW-mo/yr
|
$3.94 |
| Natural Gas | $6,778 | 819 |
MMBtu
|
$8.28 |
| Wood | $1 | 4,500 |
MMBtu
|
$0.000 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $39,848 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $26,634 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $22,713 | $129,851 |
$16,349
258,684
kWh
|
$6,364
-
kW-mo/yr
|
- | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $389 | $1,595 |
$187
2,958
kWh
|
$73
-
kW-mo/yr
|
$129 | |
| 03 | 2.7135: Install occupancy sensors | $769 | $1,200 |
$769
12,169
kWh
|
- | - | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $784 | $843 |
$320
5,070
kWh
|
$29
-
kW-mo/yr
|
$435 | |
| 05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $934 | $200 |
$680
10,760
kWh
|
$254
-
kW-mo/yr
|
- | |
| 06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,526 | - |
$1,098
17,380
kWh
|
$428
-
kW-mo/yr
|
- | |
| 07 | 2.5194: Redesign process | $12,445 | $25,000 |
$8,958
141,740
kWh
|
$3,487
-
kW-mo/yr
|
- | |
| 08 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $288 | $860 |
$207
3,280
kWh
|
$81
-
kW-mo/yr
|
- | |
| TOTAL RECOMMENDED | $39,848 | $159,549 |
$28,568
452,041
kWh
|
$10,716
-
kW-mo/yr
|
$564 | ||
| TOTAL IMPLEMENTED | $26,634 | $133,349 |
$18,841
298,132
kWh
|
$7,229
-
kW-mo/yr
|
$564 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Ancillary Material Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs