Assessment Year | 2012 |
---|---|
Principal Product | Farm equipment |
NAICS | 333111: Farm Machinery and Equipment Manufacturing |
SIC | 3523: Farm Machinery and Equipment |
Sales Range | $10 M to 50M |
# of Employees | 250 |
Plant Area |
165,000
ft2
|
Annual Production | 30,000,000
lb
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | North Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $175,347 | 2,800,429 |
kWh
|
$0.063 |
Electricity Demand | $65,341 | 11,084 |
kW-mo/yr
|
$5.90 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $502,725 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $221,812 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Ancillary Material Cost Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $453 | $100 |
$1,139
16,409
kWh
|
$154
-
kW-mo/yr
|
$(-600.0) | $(-240.0) | - | |
02 | 2.4239: Eliminate or reduce compressed air usage | $1,650 | $1,040 |
$1,241
17,882
kWh
|
$409
-
kW-mo/yr
|
- | - | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,851 | $26,563 |
$4,481
85,345
kWh
|
$1,370
-
kW-mo/yr
|
- | - | - | |
04 | 2.6218: Turn off equipment when not in use | $3,659 | $441 |
$3,659
52,714
kWh
|
- | - | - | - | |
05 | 2.7134: Use photocell controls | $169 | $250 |
$169
2,436
kWh
|
- | - | - | - | |
06 | 4.424: Improve space comfort conditioning | $83,263 | $35,225 |
$(-3,997.0)
(-57,000)
kWh
|
$(-587.0)
-
kW-mo/yr
|
- | - | $87,847 | |
07 | 4.431: Train operators for maximum operating efficiency | $196,000 | $25,000 | - | - | $196,000 | - | - | |
08 | 4.513: Re-arrange equipment layout to reduce labor costs | $211,680 | $48,800 | - | - | $211,680 | - | - | |
TOTAL RECOMMENDED | $502,725 | $137,419 |
$6,692
117,786
kWh
|
$1,346
-
kW-mo/yr
|
$407,080 | $(-240.0) | $87,847 | ||
TOTAL IMPLEMENTED | $221,812 | $76,154 |
$9,448
156,904
kWh
|
$1,524
-
kW-mo/yr
|
$211,080 | $(-240.0) | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Ancillary Material Cost Savings | Primary Product Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs