Assessment Year | 2011 |
---|---|
Principal Product | Automatic doors |
NAICS | 332321: Metal Window and Door Manufacturing |
SIC | 3442: Metal Doors, Sash, Frames, Molding, and Trim Manufacturing |
Sales Range | $10 M to 50M |
# of Employees | 54 |
Plant Area |
118,930
ft2
|
Annual Production | 23,000
pieces
|
Production Hrs. Annual | 4,000
hrs
|
Location (State) | North Carolina |
View Case Study |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $77,853 | 2,011,200 |
kWh
|
$0.039 |
Electricity Demand | $53,221 | 5,009 |
kW-mo/yr
|
$10.63 |
Electricity Fees | $4,375 | - |
|
- |
Natural Gas | $12,000 | 1,220 |
MMBtu
|
$9.84 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $25,909 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $24,628 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.8114: Change rate schedules or other changes in utility service | $9,700 | $100 |
$6,307
-
kWh
|
$3,393
-
kW-mo/yr
|
- | - | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $13,126 | $45,273 |
$7,933
204,938
kWh
|
$5,751
-
kW-mo/yr
|
- | - | $(-558.0) | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $504 | $409 |
$309
7,986
kWh
|
$195
-
kW-mo/yr
|
- | - | - | |
04 | 2.7241: Install outside air damper / economizer on hvac unit | $1,281 | $2,625 |
$813
20,998
kWh
|
$275
-
kW-mo/yr
|
- | - | $193 | |
05 | 2.2437: Recover waste heat from equipment | $825 | $910 | - | - |
$825
-
MMBtu
|
- | - | |
06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $193 | $100 |
$204
5,263
kWh
|
$109
-
kW-mo/yr
|
- | $(-100.0) | $(-20.0) | |
07 | 2.4231: Reduce the pressure of compressed air to the minimum required | $280 | - |
$183
4,719
kWh
|
$97
-
kW-mo/yr
|
- | - | - | |
TOTAL RECOMMENDED | $25,909 | $49,417 |
$15,749
243,904
kWh
|
$9,820
-
kW-mo/yr
|
$825
-
MMBtu
|
$(-100.0) | $(-385.0) | ||
TOTAL IMPLEMENTED | $24,628 | $46,792 |
$14,936
222,906
kWh
|
$9,545
-
kW-mo/yr
|
$825
-
MMBtu
|
$(-100.0) | $(-578.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs