Assessment Year 2008
Principal Product Cosmetics
NAICS 325620: Toilet Preparation Manufacturing
SIC 2844: Perfumes, Cosmetics, and Other Toilet Preparations
Sales Range $100
M
to 500
M
# of Employees 650
Plant Area 446,000
ft2
Annual Production 254,000,000
pieces
Production Hrs. Annual 8,736
hrs
Location (State) Arkansas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $1,743,275 20,748,902
kWh
Natural Gas $378,888 39,339
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $695,822 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $131,090

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings Personnel Changes Savings
01 2.4239: Eliminate or reduce compressed air usage $463,124 $9,955 $463,124
5,512,068
kWh
- -
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $116,005 $24,680 $116,005
1,380,686
kWh
- -
03 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $93,199 $40,662 $93,199
1,109,244
kWh
- -
04 2.7111: Reduce illumination to minimum necessary levels $12,169 $2,120 $12,169
144,829
kWh
- -
05 2.2511: Insulate bare equipment $4,739 $3,400 $1,482
17,636
kWh
$3,257
-
MMBtu
-
06 2.6211: Conserve energy by efficient use of vending machines $3,670 $3,894 $3,670
43,680
kWh
- -
07 2.7142: Utilize higher efficiency lamps and/or ballasts $2,916 $1,750 $1,398
16,644
kWh
- $1,518
TOTAL RECOMMENDED $695,822 $86,461 $691,047
8,224,787
kWh
$3,257
-
MMBtu
$1,518
TOTAL IMPLEMENTED $131,090 $28,550 $129,572
1,542,159
kWh
- $1,518
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings Personnel Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs