| Assessment Year | 2011 |
|---|---|
| Principal Product | Yarn |
| NAICS | 313110: Fiber, Yarn, and Thread Mills |
| SIC | 2281: Yarn Spinning Mills |
| Sales Range | $100 M to 500M |
| # of Employees | 260 |
| Plant Area |
343,186
ft2
|
| Annual Production | 86,400,000
lb
|
| Production Hrs. Annual | 8,400
hrs
|
| Location (State) | North Carolina |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $3,996,818 | 93,038,400 |
kWh
|
$0.043 |
| Electricity Demand | $1,786,820 | 151,328 |
kW-mo/yr
|
$11.81 |
| Electricity Fees | $12,023 | - |
|
- |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $133,732 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $54,587 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Ancillary Material Cost Savings | Water Consumption Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 3.4141: Replace the chlorination stage with an oxygen or ozone stage | $51,507 | $142,273 |
$(-3,633.0)
(-84,578)
kWh
|
$(-1,381.0)
-
kW-mo/yr
|
- | $75,361 |
$(-18,840.0)
-
Tgal
|
|
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $30,681 | $112,768 |
$24,527
570,931
kWh
|
$9,665
-
kW-mo/yr
|
- | $(-3,511.0) | - | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,430 | $4,435 |
$1,743
40,572
kWh
|
$687
-
kW-mo/yr
|
- | - | - | |
| 04 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $16,685 | $78,795 |
$13,940
324,497
kWh
|
$2,745
-
kW-mo/yr
|
- | - | - | |
| 05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,791 | $100 |
$4,038
93,996
kWh
|
$1,593
-
kW-mo/yr
|
$(-600.0) | $(-240.0) | - | |
| 06 | 2.2437: Recover waste heat from equipment | $27,638 | $74,990 |
$21,061
490,250
kWh
|
$6,577
-
kW-mo/yr
|
- | - | - | |
| TOTAL RECOMMENDED | $133,732 | $413,361 |
$61,676
1,435,668
kWh
|
$19,886
-
kW-mo/yr
|
$(-600.0) | $71,610 |
$(-18,840.0)
-
Tgal
|
||
| TOTAL IMPLEMENTED | $54,587 | $196,098 |
$44,248
1,029,996
kWh
|
$14,690
-
kW-mo/yr
|
$(-600.0) | $(-3,751.0) | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Ancillary Material Cost Savings | Water Consumption Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs