Assessment Year | 2004 |
---|---|
Principal Product | Knit elastic fabric |
NAICS | 313240: Knit Fabric Mills |
SIC | 2258: Lace and Warp Knit Fabric Mills |
Sales Range | $10 M to 50M |
# of Employees | 50 |
Plant Area |
120,000
ft2
|
Annual Production | 3,000,000
lb
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | North Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $252,181 | 9,045,360 |
kWh
|
$0.028 |
Electricity Demand | $251,714 | 17,395 |
kW-mo/yr
|
$14.47 |
Electricity Fees | $18,869 | - |
|
- |
Fuel Oil #6 | $268,333 | 46,419 |
MMBtu
|
$5.78 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $18,941 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $13,268 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.2625: Chill water to the highest temperature possible | $1,985 | $1,000 |
$488
17,475
kWh
|
$1,497
-
kW-mo/yr
|
|
02 | 2.7241: Install outside air damper / economizer on hvac unit | $2,558 | $5,000 |
$2,558
116,946
kWh
|
- | |
03 | 2.6218: Turn off equipment when not in use | $9,308 | $100 |
$5,475
196,224
kWh
|
$3,833
-
kW-mo/yr
|
|
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,688 | $6,890 |
$1,730
62,010
kWh
|
$1,958
-
kW-mo/yr
|
|
05 | 2.7135: Install occupancy sensors | $1,402 | $4,751 |
$1,320
47,326
kWh
|
$82
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $18,941 | $17,741 |
$11,571
439,981
kWh
|
$7,370
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $13,268 | $9,851 |
$9,353
360,496
kWh
|
$3,915
-
kW-mo/yr
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs