Assessment Year | 2002 |
---|---|
Principal Product | Cigarette filters |
NAICS |
n/a
|
SIC | 2110: |
Sales Range | $10 M to 50M |
# of Employees | 150 |
Plant Area |
81,600
ft2
|
Annual Production | 7,500,000,000
pieces
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | North Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $144,476 | 5,272,936 |
kWh
|
$0.027 |
Electricity Demand | $101,283 | 10,802 |
kW-mo/yr
|
$9.38 |
Electricity Fees | $8,345 | - |
|
- |
Natural Gas | $19,932 | 2,863 |
MMBtu
|
$6.96 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $22,529 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $6,370 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|---|
01 | 2.2437: Recover waste heat from equipment | $4,196 | $11,000 | - | - |
$4,196
-
MMBtu
|
- | - | - | - | |
02 | 2.2437: Recover waste heat from equipment | $11,658 | $10,000 |
$11,658
492,087
kWh
|
- | - | - | - | - | - | |
03 | 2.1331: Burn a less expensive grade of fuel | $3,154 | $7,500 |
$6,165
225,000
kWh
|
$4,239
-
kW-mo/yr
|
$(-6,750.0)
-
MMBtu
|
- | - | $(-500.0) | - | |
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,851 | $100 |
$1,097
40,052
kWh
|
$754
-
kW-mo/yr
|
- | - | - | - | - | |
05 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $438 | $500 | - | - | - |
$438
-
lb
|
- | - | - | |
06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $909 | $887 |
$538
19,653
kWh
|
$371
-
kW-mo/yr
|
- | - | - | - | - | |
07 | 2.7124: Make a practice of turning off lights when not needed | $323 | $760 |
$202
7,360
kWh
|
$52
-
kW-mo/yr
|
- | - | $48 | - | $21 | |
TOTAL RECOMMENDED | $22,529 | $30,747 |
$19,660
784,152
kWh
|
$5,416
-
kW-mo/yr
|
$(-2,554.0)
-
MMBtu
|
$438
-
lb
|
$48 | $(-500.0) | $21 | ||
TOTAL IMPLEMENTED | $6,370 | $11,860 |
$1,299
47,412
kWh
|
$806
-
kW-mo/yr
|
$4,196
-
MMBtu
|
- | $48 | - | $21 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs