Assessment Year | 2001 |
---|---|
Principal Product | Industrial valves |
NAICS |
n/a
|
SIC | 3491: Industrial Valves |
Sales Range | $10 M to 50M |
# of Employees | 150 |
Plant Area |
70,000
ft2
|
Annual Production | 3,000,000
pieces
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | North Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $45,127 | 1,656,194 |
kWh
|
$0.027 |
Electricity Demand | $44,230 | 4,397 |
kW-mo/yr
|
$10.06 |
Electricity Fees | $3,559 | - |
|
- |
Natural Gas | $17,179 | 2,270 |
MMBtu
|
$7.57 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $26,546 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $10,603 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Personnel Changes Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $373 | $100 |
$220
8,091
kWh
|
$153
-
kW-mo/yr
|
- | - | - | - | |
02 | 2.2437: Recover waste heat from equipment | $2,202 | $2,000 | - | - | - |
$2,202
-
MMBtu
|
- | - | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $589 | $270 |
$348
12,792
kWh
|
$241
-
kW-mo/yr
|
- | - | - | - | |
04 | 2.4239: Eliminate or reduce compressed air usage | $204 | $525 |
$72
2,633
kWh
|
$132
-
kW-mo/yr
|
- | - | - | - | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $7,083 | $32,849 |
$3,842
141,244
kWh
|
$3,241
-
kW-mo/yr
|
- | - | - | - | |
06 | 2.2511: Insulate bare equipment | $307 | $65 | - | - | - |
$307
-
MMBtu
|
- | - | |
07 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $1,568 | - | - |
$1,413
-
kW-mo/yr
|
$155 | - | - | - | |
08 | 2.5194: Redesign process | $9,810 | $40,000 |
$1,366
50,208
kWh
|
$944
-
kW-mo/yr
|
- | - | $5,000 | $2,500 | |
09 | 2.7228: Avoid introducing hot, humid, or dirty air into hvac system | $1,200 | $2,500 | - | - | - |
$1,300
-
MMBtu
|
- | $(-100.0) | |
10 | 2.7241: Install outside air damper / economizer on hvac unit | $3,210 | $6,000 |
$3,210
118,000
kWh
|
- | - | - | - | - | |
TOTAL RECOMMENDED | $26,546 | $84,309 |
$9,058
332,968
kWh
|
$6,124
-
kW-mo/yr
|
$155 |
$3,809
-
MMBtu
|
$5,000 | $2,400 | ||
TOTAL IMPLEMENTED | $10,603 | $40,795 |
$1,786
65,633
kWh
|
$1,317
-
kW-mo/yr
|
- | - | $5,000 | $2,500 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Personnel Changes Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs