| Assessment Year | 2000 |
|---|---|
| Principal Product | Denim fabric |
| NAICS |
n/a
|
| SIC | 2210: |
| Sales Range | $50 M to 100M |
| # of Employees | 700 |
| Plant Area |
500,000
ft2
|
| Annual Production | 1,300
thousand feet
|
| Production Hrs. Annual | 6,000
hrs
|
| Location (State) | North Carolina |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $2,577,233 | 85,932,885 |
kWh
|
$0.030 |
| Electricity Demand | $1,200,092 | 36,764 |
kW-mo/yr
|
$32.64 |
| Electricity Fees | $156,885 | - |
|
- |
| Fuel Oil #6 | $1,183,977 | 427,091 |
MMBtu
|
$2.77 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $334,354 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Fuel Oil #6 Savings | Water Disposal Savings | Solid Waste (non-haz) Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.1133: Adjust burners for efficient operation | $16,521 | $3,000 | n/a | - | - |
$16,521
-
MMBtu
|
- | - |
| 02 | 2.1232: Keep boiler tubes clean | $16,531 | $15,000 | n/a | - | - |
$16,531
-
MMBtu
|
- | - |
| 03 | 3.5313: Increase amount of waste recovered for resale | $163 | $300 | n/a | - | - | - | - |
$163
-
lb
|
| 04 | 3.4153: Use counter current rinsing to reduce waste water | $19,521 | $8,000 | n/a | - | - |
$12,321
-
MMBtu
|
$7,200
-
Tgal
|
- |
| 05 | 2.7122: Disconnect ballasts | $2,180 | $1,800 | n/a |
$1,422
47,479
kWh
|
$758
-
kW-mo/yr
|
- | - | - |
| 06 | 2.2425: Use flue gases to heat process or service water | $202,493 | $450,000 | n/a |
$(-4,186.0)
(-139,508)
kWh
|
$(-2,120.0)
-
kW-mo/yr
|
$210,479
-
MMBtu
|
$(-1,680.0)
-
Tgal
|
- |
| 07 | 2.2444: Use hot process fluids to preheat incoming process fluids | $76,945 | $200,000 | n/a | - | - |
$76,945
-
MMBtu
|
- | - |
| TOTAL RECOMMENDED | $334,354 | $678,100 |
$(-2,764.0)
(-92,029)
kWh
|
$(-1,362.0)
-
kW-mo/yr
|
$332,797
-
MMBtu
|
$5,520
-
Tgal
|
$163
-
lb
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Fuel Oil #6 Savings | Water Disposal Savings | Solid Waste (non-haz) Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs