Assessment Year | 1999 |
---|---|
Principal Product | Painted parts |
NAICS |
n/a
|
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $1 M to 5M |
# of Employees | 11 |
Plant Area |
48,000
ft2
|
Annual Production | 50,000
pieces
|
Production Hrs. Annual | 2,000
hrs
|
Location (State) | South Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $21,245 | 443,728 |
kWh
|
$0.048 |
Electricity Demand | $8,565 | 2,202 |
kW-mo/yr
|
$3.89 |
Electricity Fees | $29 | - |
|
- |
Natural Gas | $22,821 | 4,207 |
MMBtu
|
$5.42 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $9,681 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $5,268 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Water Consumption Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.7124: Make a practice of turning off lights when not needed | $453 | $340 |
$304
6,448
kWh
|
$149
-
kW-mo/yr
|
- | - | - | - | |
02 | 2.7134: Use photocell controls | $128 | $120 |
$105
2,052
kWh
|
$23
-
kW-mo/yr
|
- | - | - | - | |
03 | 2.7131: Add area lighting switches | $121 | $640 |
$82
1,758
kWh
|
$39
-
kW-mo/yr
|
- | - | - | - | |
04 | 2.2437: Recover waste heat from equipment | $164 | $800 | - | - |
$164
-
MMBtu
|
- | - | - | |
05 | 3.4153: Use counter current rinsing to reduce waste water | $4,315 | $1,425 |
$(-36.0)
(-879)
kWh
|
$(-17.0)
-
kW-mo/yr
|
- | - |
$4,368
-
Tgal
|
- | |
06 | 4.652: Replace existing equipment with more suitable substitutes | $4,000 | $2,500 | - | - | - | $4,000 | - | - | |
07 | 4.611: Begin a practice of predictive / preventative maintenance | $500 | - | - | - | - | - | - | $500 | |
TOTAL RECOMMENDED | $9,681 | $5,825 |
$455
9,379
kWh
|
$194
-
kW-mo/yr
|
$164
-
MMBtu
|
$4,000 |
$4,368
-
Tgal
|
$500 | ||
TOTAL IMPLEMENTED | $5,268 | $1,765 |
$268
5,569
kWh
|
$132
-
kW-mo/yr
|
- | - |
$4,368
-
Tgal
|
$500 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Water Consumption Savings | Primary Product Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs