Assessment Year | 1998 |
---|---|
Principal Product | rulers and tape measures |
NAICS |
n/a
|
SIC | 3490: |
Sales Range | $50 M to 100M |
# of Employees | 350 |
Plant Area |
500,000
ft2
|
Annual Production | 7,500,000
pieces
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | North Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $536,458 | 19,164,713 |
kWh
|
$0.028 |
Electricity Demand | $389,763 | 45,845 |
kW-mo/yr
|
$8.50 |
Electricity Fees | $288,472 | - |
|
- |
Natural Gas | $137,144 | 32,744 |
MMBtu
|
$4.19 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $597,710 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (haz) Savings | Personnel Changes Savings | Administrative Changes Savings | Water Consumption Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|---|---|---|---|---|
01 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $2,913 | $15,000 | n/a |
$3,360
120,164
kWh
|
$2,004
-
kW-mo/yr
|
$(-2,451.0)
-
MMBtu
|
- | - | - | - | - |
02 | 2.2153: Close off unneeded steam lines | $2,893 | $3,000 | n/a |
$777
27,843
kWh
|
- |
$2,116
-
MMBtu
|
- | - | - | - | - |
03 | 2.7313: Recycle air for heating, ventilation and air conditioning | $2,295 | $825 | n/a |
$457
16,413
kWh
|
$721
-
kW-mo/yr
|
$1,117
-
MMBtu
|
- | - | - | - | - |
04 | 2.2614: Use cooling tower or economizer to replace chiller cooling | $1,693 | $5,000 | n/a |
$1,693
60,375
kWh
|
- | - | - | - | - | - | - |
05 | 2.6218: Turn off equipment when not in use | $1,140 | - | n/a |
$627
22,274
kWh
|
$513
-
kW-mo/yr
|
- | - | - | - | - | - |
06 | 2.1221: Replace obsolete burners with more efficient ones | $3,876 | $1,500 | n/a | - | - |
$3,876
-
MMBtu
|
- | - | - | - | - |
07 | 3.3127: Use adsorption, ion exchange to remove contaminants | $62,900 | $5,500 | n/a | - | - | - |
$12,200
-
lb
|
- | $(-12,000.0) |
$62,700
-
Tgal
|
- |
08 | 4.131: Modify process to reduce material use/cost | $520,000 | - | n/a | - | - | - | - | $(-10,000.0) | - | - | $530,000 |
TOTAL RECOMMENDED | $597,710 | $30,825 |
$6,914
247,069
kWh
|
$3,238
-
kW-mo/yr
|
$4,658
-
MMBtu
|
$12,200
-
lb
|
$(-10,000.0) | $(-12,000.0) |
$62,700
-
Tgal
|
$530,000 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (haz) Savings | Personnel Changes Savings | Administrative Changes Savings | Water Consumption Savings | Primary Product Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs