| Assessment Year | 1998 |
|---|---|
| Principal Product | Residential oil fired heaters |
| NAICS |
n/a
|
| SIC | 3433: Heating Equipment, Except Electric and Warm Air Furnaces |
| Sales Range | $10 M to 50M |
| # of Employees | 60 |
| Plant Area |
52,000
ft2
|
| Annual Production | 15,000
pieces
|
| Production Hrs. Annual | 2,000
hrs
|
| Location (State) | North Carolina |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $24,034 | 511,430 |
kWh
|
$0.047 |
| Electricity Demand | $8,481 | 1,977 |
kW-mo/yr
|
$4.29 |
| Electricity Fees | $733 | - |
|
- |
| LPG | $11,088 | 1,246 |
MMBtu
|
$8.90 |
| Fuel Oil #2 | $19,339 | 4,205 |
MMBtu
|
$4.60 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $18,316 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $18,316 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Fuel Oil #2 Savings | Water Disposal Savings | Other Liquid (non-haz) Savings | Other Liquid (haz) Savings |
|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.2514: Cover open tanks | $488 | $600 | - | - |
$488
-
MMBtu
|
- | - | - | |
| 02 | 2.2511: Insulate bare equipment | $920 | $800 | - | - |
$920
-
MMBtu
|
- | - | - | |
| 03 | 2.2531: Re-size charging openings or add movable cover or door | $409 | $1,480 |
$(-122.0)
(-2,638)
kWh
|
$(-67.0)
-
kW-mo/yr
|
$598
-
MMBtu
|
- | - | - | |
| 04 | 2.2437: Recover waste heat from equipment | $178 | $200 | - | - |
$178
-
MMBtu
|
- | - | - | |
| 05 | 3.2123: Convert to high volume low pressure (hvlp) paint guns | $13,890 | $1,500 | - | - | - | - | - |
$13,890
-
gal
|
|
| 06 | 3.1244: Reduce solution drag-out to prevent solution loss | $2,431 | - | - | - | - |
$170
-
Tgal
|
$2,261
-
gal
|
- | |
| TOTAL RECOMMENDED | $18,316 | $4,580 |
$(-122.0)
(-2,638)
kWh
|
$(-67.0)
-
kW-mo/yr
|
$2,184
-
MMBtu
|
$170
-
Tgal
|
$2,261
-
gal
|
$13,890
-
gal
|
||
| TOTAL IMPLEMENTED | $18,316 | $4,580 |
$(-122.0)
(-2,638)
kWh
|
$(-67.0)
-
kW-mo/yr
|
$2,184
-
MMBtu
|
$170
-
Tgal
|
$2,261
-
gal
|
$13,890
-
gal
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Fuel Oil #2 Savings | Water Disposal Savings | Other Liquid (non-haz) Savings | Other Liquid (haz) Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs