Assessment Year 1998
Principal Product Industrial chemicals
NAICS
n/a
SIC 2869: Industrial Organic Chemicals, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 130
Plant Area 50,000
ft2
Annual Production 75,000,000
pieces
Production Hrs. Annual 8,760
hrs
Location (State) North Carolina

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $574,046 19,800,411
kWh
Electricity Demand $263,860 31,600
kW-mo/yr
Electricity Fees $137,119 -
Fuel Oil #6 $176,907 47,629
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $138,168 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $3,467

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings LPG Savings Fuel Oil #6 Savings Other Liquid (non-haz) Savings Personnel Changes Savings
01 2.1233: Analyze flue gas for proper air/fuel ratio $3,467 $700 - - - $3,467
-
MMBtu
- -
02 4.652: Replace existing equipment with more suitable substitutes $50,294 $280,937 $21,004
724,502
kWh
$8,317
-
kW-mo/yr
- - - $20,973
03 2.2437: Recover waste heat from equipment $21,615 $25,600 $(-2,226.0)
(-76,788)
kWh
$(-2,595.0)
-
kW-mo/yr
$16,310
-
MMBtu
$10,126
-
MMBtu
- -
04 2.5123: Reduce fluid flow rates $2,040 $2,500 - - - $2,040
-
MMBtu
- -
05 4.652: Replace existing equipment with more suitable substitutes $15,191 $30,000 - - - $14,191
-
MMBtu
$1,000
-
gal
-
06 4.652: Replace existing equipment with more suitable substitutes $45,561 $55,000 $567
36,049
kWh
$(-3,006.0)
-
kW-mo/yr
- - - $48,000
TOTAL RECOMMENDED $138,168 $394,737 $19,345
683,763
kWh
$2,716
-
kW-mo/yr
$16,310
-
MMBtu
$29,824
-
MMBtu
$1,000
-
gal
$68,973
TOTAL IMPLEMENTED $3,467 $700 - - - $3,467
-
MMBtu
- -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings LPG Savings Fuel Oil #6 Savings Other Liquid (non-haz) Savings Personnel Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs