| Assessment Year | 1997 |
|---|---|
| Principal Product | saw mills |
| NAICS |
n/a
|
| SIC | 3553: Woodworking Machinery |
| Sales Range | $5 M to 10M |
| # of Employees | 46 |
| Plant Area |
48,000
ft2
|
| Annual Production | 60
pieces
|
| Production Hrs. Annual | 3,000
hrs
|
| Location (State) | North Carolina |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $14,353 | 281,653 |
kWh
|
$0.051 |
| Electricity Demand | $4,909 | 1,423 |
kW-mo/yr
|
$3.45 |
| Electricity Fees | $853 | - |
|
- |
| Fuel Oil #2 | $11,293 | 2,035 |
MMBtu
|
$5.55 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $17,396 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $12,396 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Fuel Oil #2 Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Primary Product Savings |
|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $271 | $499 |
$213
4,103
kWh
|
$58
-
kW-mo/yr
|
- | - | - | - | |
| 02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $100 | $111 |
$75
1,465
kWh
|
$25
-
kW-mo/yr
|
- | - | - | - | |
| 03 | 2.4239: Eliminate or reduce compressed air usage | $791 | $140 |
$311
6,155
kWh
|
$480
-
kW-mo/yr
|
- | - | - | - | |
| 04 | 2.4133: Use most efficient type of electric motors | $22 | $48 |
$14
293
kWh
|
$8
-
kW-mo/yr
|
- | - | - | - | |
| 05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $187 | $149 |
$107
2,052
kWh
|
$80
-
kW-mo/yr
|
- | - | - | - | |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $886 | $982 |
$864
16,999
kWh
|
$22
-
kW-mo/yr
|
- | - | - | - | |
| 07 | 2.1233: Analyze flue gas for proper air/fuel ratio | $1,289 | $600 | - | - |
$1,289
-
MMBtu
|
- | - | - | |
| 08 | 3.2123: Convert to high volume low pressure (hvlp) paint guns | $8,850 | $1,000 | - | - | - |
$8,850
-
lb
|
- | - | |
| 09 | 4.122: Develop standard procedures to improve internal yields | $5,000 | $3,600 | - | - | - | - | $(-5,000.0) | $10,000 | |
| TOTAL RECOMMENDED | $17,396 | $7,129 |
$1,584
31,067
kWh
|
$673
-
kW-mo/yr
|
$1,289
-
MMBtu
|
$8,850
-
lb
|
$(-5,000.0) | $10,000 | ||
| TOTAL IMPLEMENTED | $12,396 | $3,529 |
$1,584
31,067
kWh
|
$673
-
kW-mo/yr
|
$1,289
-
MMBtu
|
$8,850
-
lb
|
- | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Fuel Oil #2 Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Primary Product Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs