ITAC Assessment: NC0115
ITAC logo
ITAC Assessment: NC0115
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1997
Principal Product Valve stems
NAICS
n/a
SIC 3494: Valves and Pipe Fittings, Not Elsewhere Classified
Sales Range $5
M
to 10
M
# of Employees 483
Plant Area 325,000
ft2
Annual Production 135,000,000
pieces
Production Hrs. Annual 7,200
hrs
Location (State) North Carolina

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $638,079 21,275,499
kWh
Electricity Demand $459,197 44,669
kW-mo/yr
Electricity Fees $13,607 -
Natural Gas $248,108 53,663
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $40,031 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $24,391

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Solid Waste (haz) Savings Ancillary Material Cost Savings Increase in Production Savings
01 2.2414: Use waste heat from hot flue gases to preheat $21,668 $17,363 - - $21,668
-
MMBtu
- - -
02 2.7111: Reduce illumination to minimum necessary levels $1,149 $320 $696
21,981
kWh
$453
-
kW-mo/yr
- - - -
03 2.7314: Reduce ventilation air $6,190 $2,765 - - $6,190
-
MMBtu
- - -
04 2.7243: Improve air circulation with destratification fans / other methods $1,108 $4,000 $(-291.0)
(-9,379)
kWh
$(-163.0)
-
kW-mo/yr
$1,562
-
MMBtu
- - -
05 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $726 $120 $481
17,585
kWh
$245
-
kW-mo/yr
- - - -
06 2.2136: Install / repair insulation on steam lines $848 $299 - - $848
-
MMBtu
- - -
07 3.1244: Reduce solution drag-out to prevent solution loss $391 - - - - - $391 -
08 3.1244: Reduce solution drag-out to prevent solution loss $2,191 $2,000 - - - $720
-
lb
$1,471 -
09 4.424: Improve space comfort conditioning $5,760 $9,150 - - - - - $5,760
TOTAL RECOMMENDED $40,031 $36,017 $886
30,187
kWh
$535
-
kW-mo/yr
$30,268
-
MMBtu
$720
-
lb
$1,862 $5,760
TOTAL IMPLEMENTED $24,391 $18,102 $1,177
39,566
kWh
$698
-
kW-mo/yr
$22,516
-
MMBtu
- - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Solid Waste (haz) Savings Ancillary Material Cost Savings Increase in Production Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs