Assessment Year | 1997 |
---|---|
Principal Product | Lawn mowers |
NAICS |
n/a
|
SIC | 3524: Lawn and Garden Tractors and Home Lawn and Garden Equipment |
Sales Range | $50 M to 100M |
# of Employees | 289 |
Plant Area |
127,600
ft2
|
Annual Production | 201,638
pieces
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | North Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $409,889 | 9,958,968 |
kWh
|
$0.041 |
Electricity Demand | $90,840 | 28,566 |
kW-mo/yr
|
$3.18 |
Electricity Fees | $17,263 | - |
|
- |
Natural Gas | $178,194 | 42,220 |
MMBtu
|
$4.22 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $109,667 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $22,969 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Other Liquid (non-haz) Savings | Other Liquid (haz) Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $287 | $420 |
$196
4,689
kWh
|
$91
-
kW-mo/yr
|
- | - | - | - | |
02 | 2.4133: Use most efficient type of electric motors | $1,452 | $1,356 |
$1,258
30,481
kWh
|
$194
-
kW-mo/yr
|
- | - | - | - | |
03 | 2.4239: Eliminate or reduce compressed air usage | $242 | $280 |
$195
4,689
kWh
|
$47
-
kW-mo/yr
|
- | - | - | - | |
04 | 2.4239: Eliminate or reduce compressed air usage | $69,557 | $9,600 |
$60,246
1,463,658
kWh
|
$9,311
-
kW-mo/yr
|
- | - | - | - | |
05 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $38 | $100 | - | - | - | - |
$38
-
lb
|
- | |
06 | 3.3125: Use distillation, evaporation to remove contaminants | $21,230 | $15,000 |
$(-1,810.0)
(-125,733)
kWh
|
- |
$23,040
-
gal
|
- | - | - | |
07 | 3.1121: Use more efficient adhesive applicators | $16,861 | $2,000 | - | - | - |
$37,111
-
gal
|
- | $(-20,250.0) | |
TOTAL RECOMMENDED | $109,667 | $28,756 |
$60,085
1,377,784
kWh
|
$9,643
-
kW-mo/yr
|
$23,040
-
gal
|
$37,111
-
gal
|
$38
-
lb
|
$(-20,250.0) | ||
TOTAL IMPLEMENTED | $22,969 | $16,776 |
$(-356.0)
(-90,563)
kWh
|
$285
-
kW-mo/yr
|
$23,040
-
gal
|
- | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Other Liquid (non-haz) Savings | Other Liquid (haz) Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs