Assessment Year 1996
Principal Product Lumber
NAICS
n/a
SIC 2420:
Sales Range $50
M
to 100
M
# of Employees 180
Plant Area 100,000
ft2
Annual Production 154,000,000
thousand feet
Production Hrs. Annual 4,000
hrs
Location (State) North Carolina

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $742,175 20,795,428
kWh
Electricity Demand $756,557 46,072
kW-mo/yr
Electricity Fees $180,027 -
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $599,464 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $279,843

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Solid Waste (non-haz) Savings Personnel Changes Savings Ancillary Material Cost Savings
01 2.3414: Burn waste to produce steam to drive a steam turbine generator set and use steam exhaust for heat $307,788 $815,000 $142,800
4,000,000
kWh
$249,600
-
kW-mo/yr
- $(-30,000.0) $(-54,612.0)
02 2.3131: Reschedule plant operations or reduce load to avoid peaks $260,000 - - $260,000
-
kW-mo/yr
- - -
03 2.4133: Use most efficient type of electric motors $2,693 $1,795 $980
27,550
kWh
$1,713
-
kW-mo/yr
- - -
04 2.7111: Reduce illumination to minimum necessary levels $3,991 $3,200 $1,453
40,739
kWh
$2,538
-
kW-mo/yr
- - -
05 2.7134: Use photocell controls $3,024 $440 $1,150
39,273
kWh
$1,874
-
kW-mo/yr
- - -
06 2.7133: Use separate switches on perimeter lighting which may be turned off when natural light is available $3,547 - $3,547
99,355
kWh
- - - -
07 2.7142: Utilize higher efficiency lamps and/or ballasts $1,271 $5,040 $507
14,068
kWh
$404
-
kW-mo/yr
- - $360
08 3.5311: Recover and reuse waste material $17,000 $850 - - $20,750
-
lb
$(-3,750.0) -
09 3.5316: Contract a wood pallet recycling company $150 $100 - - $150
-
lb
- -
TOTAL RECOMMENDED $599,464 $826,425 $150,437
4,220,985
kWh
$516,129
-
kW-mo/yr
$20,900
-
lb
$(-33,750.0) $(-54,252.0)
TOTAL IMPLEMENTED $279,843 $2,745 $980
27,550
kWh
$261,713
-
kW-mo/yr
$20,900
-
lb
$(-3,750.0) -