Assessment Year | 1996 |
---|---|
Principal Product | Pnuematic controls |
NAICS |
n/a
|
SIC | 3490: |
Sales Range | $10 M to 50M |
# of Employees | 160 |
Plant Area |
79,000
ft2
|
Annual Production | 211,100
pieces
|
Production Hrs. Annual | 2,000
hrs
|
Location (State) | North Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $81,255 | 1,935,229 |
kWh
|
$0.042 |
Electricity Demand | $14,590 | 5,444 |
kW-mo/yr
|
$2.68 |
Electricity Fees | $21,021 | - |
|
- |
Natural Gas | $5,539 | 892 |
MMBtu
|
$6.21 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $20,408 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $16,647 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (haz) Savings | Solid Waste (non-haz) Savings | Primary Raw Material Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|---|
01 | 2.7314: Reduce ventilation air | $1,513 | $4,305 |
$221
5,275
kWh
|
$65
-
kW-mo/yr
|
$1,227
-
MMBtu
|
- | - | - | - | |
02 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $965 | - | - |
$965
-
kW-mo/yr
|
- | - | - | - | - | |
03 | 2.7232: Replace existing hvac unit with high efficiency model | $862 | $1,500 |
$567
13,482
kWh
|
$295
-
kW-mo/yr
|
- | - | - | - | - | |
04 | 2.7124: Make a practice of turning off lights when not needed | $1,789 | $2,100 |
$1,789
42,497
kWh
|
- | - | - | - | - | - | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $796 | $1,839 |
$623
14,947
kWh
|
$173
-
kW-mo/yr
|
- | - | - | - | - | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $487 | $2,100 |
$310
7,327
kWh
|
$27
-
kW-mo/yr
|
- | - | - | - | $150 | |
07 | 3.2123: Convert to high volume low pressure (hvlp) paint guns | $10,542 | $1,800 | - | - | - |
$1,400
-
gal
|
$172
-
lb
|
$8,970 | - | |
08 | 3.3122: Use filtration, centrifuging to remove contaminants | $94 | $750 | - | - | - |
$94
-
gal
|
- | - | - | |
09 | 3.1241: Slow insertion / withdrawal of parts from degreasing tank | $3,360 | $8,500 |
$(-470.0)
(-11,137)
kWh
|
$(-180.0)
-
kW-mo/yr
|
- |
$4,010
-
gal
|
- | - | - | |
TOTAL RECOMMENDED | $20,408 | $22,894 |
$3,040
72,391
kWh
|
$1,345
-
kW-mo/yr
|
$1,227
-
MMBtu
|
$5,504
-
gal
|
$172
-
lb
|
$8,970 | $150 | ||
TOTAL IMPLEMENTED | $16,647 | $14,650 |
$1,886
44,842
kWh
|
$115
-
kW-mo/yr
|
- |
$5,504
-
gal
|
$172
-
lb
|
$8,970 | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (haz) Savings | Solid Waste (non-haz) Savings | Primary Raw Material Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs