Assessment Year 1996
Principal Product Coatings
NAICS
n/a
SIC 2851: Paints, Varnishes, Lacquers, Enamels, and Allied Products
Sales Range $50
M
to 100
M
# of Employees 115
Plant Area 60,000
ft2
Annual Production 2,600
Tgal
Production Hrs. Annual 8,760
hrs
Location (State) North Carolina

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $188,975 4,755,276
kWh
Electricity Demand $73,897 10,235
kW-mo/yr
Electricity Fees $19,567 -
Natural Gas $56,569 11,792
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $18,681 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $2,085

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Water Disposal Savings Solid Waste (non-haz) Savings Ancillary Material Cost Savings
01 2.2625: Chill water to the highest temperature possible $144 - $144
3,517
kWh
- - - - -
02 2.2492: Use "heat wheel" or other heat exchanger to cross-exchange building exhaust air with make-up air $14,587 $25,400 - - $14,587
-
MMBtu
- - -
03 2.1233: Analyze flue gas for proper air/fuel ratio $738 $600 - - $738
-
MMBtu
- - -
04 2.8118: Check for accuracy of utility / power meters $594 - - - - $594
-
Tgal
- -
05 2.7142: Utilize higher efficiency lamps and/or ballasts $910 $520 $289
7,327
kWh
$72
-
kW-mo/yr
- - - $549
06 2.7134: Use photocell controls $1,271 - $637
16,120
kWh
$634
-
kW-mo/yr
- - - -
07 3.1162: Use less wasteful packaging $437 - - - - - $437
-
lb
-
TOTAL RECOMMENDED $18,681 $26,520 $1,070
26,964
kWh
$706
-
kW-mo/yr
$15,325
-
MMBtu
$594
-
Tgal
$437
-
lb
$549
TOTAL IMPLEMENTED $2,085 $1,120 $289
7,327
kWh
$72
-
kW-mo/yr
$738
-
MMBtu
- $437
-
lb
$549
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Water Disposal Savings Solid Waste (non-haz) Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs